Eaton Moeller series NZM Undervoltage release, 2early N/O, for delay unit, +cable
| Product Name |
Eaton Moeller series NZM Undervoltage release
|
| Catalog Number |
271609
|
| EAN |
4015082716097
|
| Product Length/Depth |
37 mm
|
| Product Height |
66 mm
|
| Product Width |
32 mm
|
| Product Weight |
0.17 kg
|
| Compliances |
IEC
RoHS conform |
| Certifications |
UL489
CSA (Class No. 1437-01) UL (File No. E140305) CE marking IEC60947 UL listed CSA-C22.2 No. 5-09 UL (Category Control Number DIHS) CSA (File No. 22086) CSA certified |
| Model Code |
NZM1-XUVHIV20L
|
| Used with |
N(S)1(-4)
NZM1(-4) |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Screw connection
|
| Fitted with: |
Two separate early-make auxiliary contacts
|
| Frame |
NZM1
|
| Number of contacts (normally open contacts) |
2
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
| Voltage rating at DC |
18 V DC
|
| Suitable for |
Off-load switch
|
| Connection type |
With 3 m loose connection cable instead of screw termination
|
| Voltage type |
AC
|
| Functions |
Delayed
|
| Terminal capacity (solid/flexible conductor) |
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) at shunt release 0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule 18 - 14 AWG (2x) at shunt release 0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule 18 - 14 AWG (2x) for undervoltage releases, off-delayed 0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule 18 - 14 AWG (1x) for undervoltage releases, off-delayed |
| Type |
Accessory
Undervoltage release
Undervoltage release for use with delay unit UVU
|
| Special features |
Combination of separate delay unit and special releases.
For use with emergency-stop devices in connection with an emergency-stop button.
not UL/CSA approved
Special releases for combining with separate delay time.
UVU-NZM delay unit is additionally required.
Cannot be installed simultaneously with separate NZM...-XHIV early-make auxiliary contact or NZM...-XA... shunt release.
Cannot be used in conjunction with NZM...-XR... remote operator.
Early make of auxiliary contact on switching on and off (manual operation): approx. 20 ms.
|
| Rated control supply voltage (Us) at DC - max |
0 V
|
| Rated control supply voltage (Us) at DC - min |
0 V
|
| Number of contacts (normally closed contacts) |
0
|
| Number of contacts (change-over contacts) |
0
|
| Undelayed short-circuit release - min |
0 A
|
| Undelayed short-circuit release - max |
0 A
|