Eaton Moeller® series DILAT Contactor relay, 24 V 50/60 Hz, 3 N/O, Screw terminals, AC operation
| Product Name |
Eaton Moeller® series DILAT Control relay
|
| Catalog Number |
197624
|
| EAN |
4015081945030
|
| Product Length/Depth |
77.5 mm
|
| Product Height |
70.1 mm
|
| Product Width |
27 mm
|
| Product Weight |
0.175 kg
|
| Certifications |
IEC/EN 60947
VDE 0660 |
| Model Code |
DILAT-30(24V50/60HZ)
|
| Application |
Contactor relays
|
| Connection |
Screw terminals
|
| Connection to SmartWire-DT |
No
|
| Degree of protection |
IP20
|
| Lifespan, mechanical |
10,000,000 Operations (AC operated)
|
| Mounting method |
DIN-rail/screw
|
| Operating frequency |
3600 Operations/h
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Product category |
DILAT Contactor relays
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| Rated impulse withstand voltage (Uimp) |
6000 V AC
|
| Voltage type |
AC
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
55 °C
|
| Ambient storage temperature - min |
40 °C
|
| Ambient storage temperature - max |
80 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Terminal capacity (flexible with ferrule) |
2 x (0.75 - 2.5) mm²
1 x (0.75 - 2.5) mm² |
| Terminal capacity (solid) |
2 x (0.75 - 2.5) mm²
1 x (0.75 - 2.5) mm² |
| Stripping length (main cable) |
14 mm
|
| Screwdriver size |
2, Terminal screw, Pozidriv screwdriver
|
| Tightening torque |
0.8 Nm, Screw terminals
|
| Rated insulation voltage (Ui) |
690 V
|
| Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
4 A
|
| Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V |
1.9 A
|
| Rated operational current (Ie) at AC-15, 500 V |
1.4 A
|
| Rated operational voltage (Ue) at AC - max |
690 V
|
| Pick-up voltage |
0.85 - 1.1 V AC x Uc
0.85 - 1.1 V AC x Uc (voltage tolerance - dual frequency coil 50/60 Hz) |
| Power consumption, pick-up, 60 Hz |
30 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
|
| Power consumption, sealing, 50 Hz |
2 W, Dual-frequency coil in a cold state and 1.0 x Us
6 VA, Dual-frequency coil in a cold state and 1.0 x Us |
| Power consumption, sealing, 60 Hz |
2 W, Dual-frequency coil in a cold state and 1.0 x Us
6 VA, Dual-frequency coil in a cold state and 1.0 x Us |
| Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
24 V
|
| Switching time (AC operated, make contacts, closing delay) - min |
20 ms
|
| Switching time (AC operated, make contacts, closing delay) - max |
25 ms
|
| Switching time (AC operated, make contacts, opening delay) - min |
9 ms
|
| Switching time (AC operated, make contacts, opening delay) - max |
13 ms
|
| Number of auxiliary contacts (normally closed contacts) |
0
|
| Number of auxiliary contacts (normally open contacts) |
3
|
| Number of contacts (normally open contacts) |
3
|