Eaton Moeller® series MCS Pressure switch, 1W, 15bar MCS11-U
Product Name |
Eaton Moeller® series MCS Pressure switch
|
Catalog Number |
090900
|
Product Length/Depth |
96 mm
|
Product Height |
111 mm
|
Product Width |
60 mm
|
Product Weight |
0.28 kg
|
Certifications |
IEC/EN 60947-5-1
|
Catalog Notes |
Note on use: This product complies with Low-Voltage Directive 2014/35/EC and EMC Directive 2014/30/EC and meets the requirements in EN 60947-5-1. This product does not meet the rail industry's standard requirements. Accordingly, the user must review it separately for the specific application at hand.
|
Electric connection type |
Screw connection
|
Features |
Variable switching differential
|
Actuator diameter |
0 mm
|
Bursting pressure |
90 bar
|
Connection |
Inner thread gas cylindrical (BSPP)
|
Connection type |
Tunnel terminal
|
Degree of protection |
IP65
NEMA Other |
Operating pressure - max |
15000 hPa
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Pressure switches
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Suitable as |
2-point controller
Guard |
Test pressure |
32 bar
|
Mounting position |
As required
|
Shock resistance |
10 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
|
Vibration resistance |
36 Hz, Amplitude 1 mm, (IEC/EN 60068-2-6)
|
Ambient operating temperature - min |
25 °C
|
Ambient operating temperature - max |
70 °C
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacity (flexible with ferrule) |
1 x (0.5 - 1.5) mm², ferrules to DIN 46228
|
Terminal capacity (solid) |
1 x (0.75 - 2.5) mm²
|
Screw size |
M3, Terminal screw
|
Tightening torque |
0.5 Nm, Screw terminals
|
Rated frequency - max |
50 Hz
|
Rated insulation voltage (Ui) |
400 V
|
Rated operational current (Ie) |
0.25 A at DC-13, 110 V
2 A at DC-13, 24 V |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
0 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
0 A
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
0 kW
|
Rated operational voltage (Ue) at AC - min |
0 V
|
Rated operational voltage (Ue) at AC - max |
230 V
|
Rated operational voltage (Ue) at DC - min |
0 V
|
Rated operational voltage (Ue) at DC - max |
110 V
|
Short-circuit protection rating |
Max. 10 A gG/gL, Fuse, Contacts
|
Number of auxiliary contacts (change-over contacts) |
1
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|