Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 6.8 kW, 1 N/O, 1 NC, 24 V 50/60 Hz, AC operation, Push in terminals
Product Name |
Eaton Moeller® series DILM contactor
|
Catalog Number |
199276
|
Product Length/Depth |
115 mm
|
Product Height |
85 mm
|
Product Width |
45 mm
|
Product Weight |
0.441 kg
|
Certifications |
VDE 0660
IEC/EN 60947 UL Listed CSA certified UL Category Control No.: NLDX CE marking UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 CSA File No.: 012528 |
Catalog Notes |
Also tested according to AC-3e.
|
Fitted with: |
Mirror contact
|
Number of poles |
Three-pole
|
Application |
Contactors for Motors
|
Frame size |
FS2
|
Lifespan, mechanical |
10,000,000 Operations (AC operated)
|
Operating frequency |
5000 mechanical Operations/h (AC operated)
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Contactors
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Rated impulse withstand voltage (Uimp) |
8000 V AC
|
Suitable for |
Also motors with efficiency class IE3
|
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-3: Normal AC induction motors: starting, switch off during running |
Voltage type |
AC
|
Shock resistance |
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 6.5 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 8 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 2 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature (enclosed) - min |
-25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
80 °C
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Emitted interference |
According to EN 60947-1
|
Interference immunity |
According to EN 60947-1
|
Terminal capacity (flexible with unisolated ferrule) |
1 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.5 - 2.5) mm², Control circuit cables 2 x (0.5 - 2.5) mm², Control circuit cables 1 x (1 - 6) mm², Main cables 2 x (1 - 6) mm², Main cables |
Terminal capacity (flexible with ferrule) |
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm² |
Terminal capacity (flexible) |
2 x (1-6) mm²
1 x (0.5 - 2.5) mm² 1 x (1 - 10) mm² 2 x (0.5 - 2.5) mm² |
Terminal capacity (solid) |
1 x (1 - 6) mm²
1 x (0.5 - 0.25) mm² 2 x (0.5 - 2.5) mm², Control circuit cables 2 x (1 - 6) mm² |
Terminal capacity (solid/stranded AWG) |
18 - 8, Main cables
20 - 14 |
Screwdriver size |
3 x 0.5 mm, Terminal screw
3.0 x 0.5 mm, Terminal screw |
Rated breaking capacity at 220/230 V |
120 A
|
Rated breaking capacity at 380/400 V |
120 A
|
Rated breaking capacity at 500 V |
100 A
|
Rated breaking capacity at 660/690 V |
70 A
|
Rated operational current (Ie) |
14 A at AC-3, 220/230 V
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
40 A
|
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
14 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
14 A
|
Rated operational current (Ie) at AC-3, 440 V |
14 A
|
Rated operational current (Ie) at AC-3, 500 V |
10 A
|
Rated operational current (Ie) at AC-3, 660 V, 690 V |
7 A
|
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V |
7 A
|
Rated operational current (Ie) at AC-4, 400 V |
7 A
|
Rated operational current (Ie) at AC-4, 500 V |
6 A
|
Rated operational current (Ie) at AC-4, 660 V, 690 V |
5 A
|