Eaton Moeller® series FAK Palm switch, 1N/O+1N/C, mushroom red, surface mounting FAK-R/KC11/I
Product Name |
Eaton Moeller® series FAK Palm switch
|
Catalog Number |
229746
|
Model Code |
FAK-R/KC11/I
|
EAN |
4015082297466
|
Product Length/Depth |
85 mm
|
Product Height |
85 mm
|
Product Width |
100 mm
|
Product Weight |
0.324 kg
|
Certifications |
CSA-C22.2 No. 94-91
CSA CSA File No.: 012528 UL File No.: E29184 CSA Class No.: 3211-03 IEC/EN 60947-5 IEC/EN 60947-5-1 UL Category Control No.: NKCR VDE 0660 UL CE CSA-C22.2 No. 14-05 UL 508 |
Catalog Notes |
Contacts with safety function, by positive opening to IEC/EN 60947-5-1
|
Enclosure color |
Gray
Black |
Unlocking method |
None
|
Connection to SmartWire-DT |
No
|
Degree of protection |
IP67/IP69K
NEMA 4X |
Lifespan, mechanical |
1,000,000 Operations (AC operated)
|
Mounting position |
As required
|
Opening diameter |
0 mm
|
Operating frequency |
3600 Operations/h
|
Product category |
Foot and palm switches
|
Shock resistance |
15 g, Mechanical, According to IEC/EN 60068-2-27, Half-Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27 |
Type |
Complete device
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Actuating force |
40 N
|
Actuator color |
Red
|
Actuator function |
Momentary
Spring-return |
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.11 W
|
Rated operational current for specified heat dissipation (In) |
6 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|