Reset
Eaton Moeller series NZM - Molded Case Circuit Breaker. Molded Case Switch, 3p, 1200A
Product Name |
Eaton Moeller series NZM molded case switch
|
Catalog Number |
102691
|
Product Length/Depth |
401 mm
|
Product Height |
207 mm
|
Product Width |
210 mm
|
Product Weight |
21 kg
|
Compliances |
RoHS conform
|
Certifications |
Specially designed for North America
CSA (File No. 22086) CSA-C22.2 No. 5-09 UL (File No. E148671) UL listed IEC 60947-2 CE marking UL 489 IEC CSA (Class No. 4652-06) UL/CSA UL (Category Control Number WJAZ) CSA certified |
Voltage rating |
690 V - 690 V
|
Rated operating voltage Ue (UL) - max |
600 V
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Current rating (Iu) (UL 489 csa 22.2 no. 5.1) |
1200 A
|
Rated current (Iu) |
1200 A
|
Amperage Rating |
1200 A
|
Instantaneous current setting (Ii) - min |
25000 A
|
Instantaneous current setting (Ii) - max |
25000 A
|
Overload current setting (Ir) - min |
0 A
|
Overload current setting (Ir) - max |
0 A
|
Short delay current setting (Isd) - min |
0 A
|
Short delay current setting (Isd) - max |
0 A
|
Short-circuit release non-delayed setting - min |
25000 A
|
Short-circuit release non-delayed setting - max |
25000 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
43 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
35 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
33 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
20 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
18 kA
|
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
187 kA
|
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
154 kA
|
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
143 kA
|
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
84 kA
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
74 kA
|
Short-circuit total breaktime |
< 25 ms (≦ 415 V); < 35 ms (> 415 V)
|
Electrical connection type of main circuit |
Screw connection
|
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
2000 operations at 415 V AC-1
1000 operations at 690 V AC-3 2000 operations at 400 V AC-3 3000 operations at 400 V AC-1 2000 operations at 415 V AC-3 2000 operations at 690 V AC-1 |
Direction of incoming supply |
As required
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Current rating (Iu) (UL 489 csa 22.2 no. 5.1) |
1200 A
|
Rated current (Iu) |
1200 A
|
Amperage Rating |
1200 A
|
Instantaneous current setting (Ii) - min |
25000 A
|
Instantaneous current setting (Ii) - max |
25000 A
|
Overload current setting (Ir) - min |
0 A
|
Overload current setting (Ir) - max |
0 A
|
Short delay current setting (Isd) - min |
0 A
|
Short delay current setting (Isd) - max |
0 A
|
Short-circuit release non-delayed setting - min |
25000 A
|
Short-circuit release non-delayed setting - max |
25000 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
43 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
35 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
33 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
20 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
18 kA
|
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
187 kA
|
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
154 kA
|
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
143 kA
|
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
84 kA
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
74 kA
|
Short-circuit total breaktime |
< 25 ms (≦ 415 V); < 35 ms (> 415 V)
|
Electrical connection type of main circuit |
Screw connection
|
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
2000 operations at 415 V AC-1
1000 operations at 690 V AC-3 2000 operations at 400 V AC-3 3000 operations at 400 V AC-1 2000 operations at 415 V AC-3 2000 operations at 690 V AC-1 |
Direction of incoming supply |
As required
|
Mounting Method |
Built-in device fixed built-in technique
Fixed DIN rail (top hat rail) mounting optional |
Degree of protection |
IP20
In the area of the HMI devices: IP20 (basic protection type) |
Degree of protection (IP), front side |
IP66 (with door coupling rotary handle)
IP40 (with insulating surround) |
Degree of protection (terminations) |
IP10 (tunnel terminal)
IP00 (terminations, phase isolator and band terminal) |
Number of auxiliary contacts (change-over contacts) |
0
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Position of connection for main current circuit |
Front side
|
Switch positions |
I, +, 0
|
Lifespan, mechanical |
10000 operations
|