Eaton Moeller® series DILMP Contactor, 4 pole, 200 A, RDC 24: 24 - 27 V DC, DC operation
| Product Name |
Eaton Moeller® series DILMP 4-pole contactor
|
| Catalog Number |
109930
|
| Product Length/Depth |
160 mm
|
| Product Height |
170 mm
|
| Product Width |
122 mm
|
| Product Weight |
2.73 kg
|
| Certifications |
CE
CSA-C22.2 No. 60947-4-1-14 IEC/EN 60947 UL Category Control No.: NLDX CSA CSA File No.: 012528 UL 60947-4-1 CSA Class No.: 2411-03, 3211-04 UL File No.: E29096 VDE 0660 IEC/EN 60947-4-1 UL |
| Catalog Notes |
Also tested according to AC-3e.
|
| Fitted with: |
Suppressor circuit in actuating electronics
|
| Number of poles |
Four-pole
|
| Application |
Contactors for 4 pole electric consumers
|
| Lifespan, mechanical |
10,000,000 Operations (AC operated)
10,000,000 Operations (DC operated) |
| Operating frequency |
3600 mechanical Operations/h (AC operated)
3600 mechanical Operations/h (DC operated) |
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Product category |
Contactors
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| Rated impulse withstand voltage (Uimp) |
8000 V AC
|
| Residual current |
1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
|
| Resistance per pole |
0.6 mΩ
|
| Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running |
| Voltage type |
DC
|
| Shock resistance |
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
60 °C
|
| Ambient operating temperature (enclosed) - min |
-25 °C
|
| Ambient operating temperature (enclosed) - max |
40 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Ambient storage temperature - max |
80 °C
|
| Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-3 |
| Interference immunity |
According to EN 60947-1
|
| Terminal capacity (copper band) |
2 x (6 x 16 x 0.8) mm (Number of segments x width x thickness), Main cables
|
| Terminal capacity (flexible with ferrule) |
1 x (0.75 - 1.5) mm²
2 x (0.75 - 1.5) mm² |
| Terminal capacity (flexible) |
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid) |
1 x (0.75 - 4) mm², Control circuit cables
2 x (0.75 - 4) mm², Control circuit cables 1 x (0.75 - 2.5) mm² |
| Terminal capacity (solid/stranded AWG) |
18 - 14, Control circuit cables
8 - 3/0, Main cables |
| Terminal capacity (stranded) |
1 x (16 - 120) mm², Main cables
2 x (16 - 95) mm², Main cables |
| Stripping length (main cable) |
15 mm
|
| Stripping length (control circuit cable) |
10 mm
|
| Screw size |
M10, Terminal screw, Main cables
5 mm AF, Hexagon socket-head spanner, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables |
| Screwdriver size |
2, Terminal screw, Control circuit cables, Pozidriv screwdriver
0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver |
| Tightening torque |
14 Nm, Screw terminals, Main cables
1.2 Nm, Screw terminals, Control circuit cables |
| Rated breaking capacity at 220/230 V |
1150 A
|
| Rated breaking capacity at 380/400 V |
1150 A
|
| Rated breaking capacity at 500 V |
1150 A
|
| Rated breaking capacity at 660/690 V |
800 A
|
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
200 A
|
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
115 A
|
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
115 A
|
| Rated operational current (Ie) at AC-3, 440 V |
115 A
|
| Rated operational current (Ie) at AC-3, 500 V |
115 A
|
| Rated operational current (Ie) at AC-3, 660 V, 690 V |
93 A
|
| Rated operational current (Ie) at AC-4, 400 V |
136 A
|
| Rated operational current (Ie) at DC-1, 60 V |
200 A
|
| Rated operational current (Ie) at DC-1, 110 V |
200 A
|