Reset
Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 40A, plug-in module, H1-S40-SVE
| Product Name |
Eaton Moeller series NZM molded case circuit breaker magnetic
|
| Catalog Number |
112805
|
| Product Length/Depth |
84.5 mm
|
| Product Height |
145 mm
|
| Product Width |
90 mm
|
| Product Weight |
1.227 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC
IEC/EN 60947 |
| Voltage rating |
690 V - 690 V
|
| Rated insulation voltage (Ui) |
690 V
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
6000 V
|
| Rated operational current |
36 A (400 V AC-3)
|
| Amperage Rating |
40 A
|
| Instantaneous current setting (Ii) - min |
8 A
|
| Instantaneous current setting (Ii) - max |
14 A
|
| Overload current setting (Ir) - min |
0 A
|
| Overload current setting (Ir) - max |
0 A
|
| Short-circuit release non-delayed setting - min |
320 A
|
| Short-circuit release non-delayed setting - max |
560 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
100 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
35 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
35 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
10 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
7.5 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
220 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
220 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
154 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
40 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
17 kA
|
| Rated operating power at AC-3, 230 V |
11 kW
|
| Rated operating power at AC-3, 400 V |
18.5 kW
|
| Short-circuit total breaktime |
< 10 ms
|
| Electrical connection type of main circuit |
Other
|
| Isolation |
500 V AC (between auxiliary contacts and main contacts)
300 V AC (between the auxiliary contacts) |
| Number of operations per hour - max |
120
|
| Handle type |
Rocker lever
|
| Utilization category |
A (IEC/EN 60947-2)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
10000 operations at 400 V AC-1
10000 operations at 415 V AC-1 5000 operations at 690 V AC-3 7500 operations at 415 V AC-3 7500 operations at 400 V AC-3 7500 operations at 690 V AC-1 |
| Direction of incoming supply |
As required
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
6000 V
|
| Rated operational current |
36 A (400 V AC-3)
|
| Amperage Rating |
40 A
|
| Instantaneous current setting (Ii) - min |
8 A
|
| Instantaneous current setting (Ii) - max |
14 A
|
| Overload current setting (Ir) - min |
0 A
|
| Overload current setting (Ir) - max |
0 A
|
| Short-circuit release non-delayed setting - min |
320 A
|
| Short-circuit release non-delayed setting - max |
560 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
100 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
35 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
35 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
10 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
7.5 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
220 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
220 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
154 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
40 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
17 kA
|
| Rated operating power at AC-3, 230 V |
11 kW
|
| Rated operating power at AC-3, 400 V |
18.5 kW
|
| Short-circuit total breaktime |
< 10 ms
|
| Electrical connection type of main circuit |
Other
|
| Isolation |
500 V AC (between auxiliary contacts and main contacts)
300 V AC (between the auxiliary contacts) |
| Number of operations per hour - max |
120
|
| Handle type |
Rocker lever
|
| Utilization category |
A (IEC/EN 60947-2)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
10000 operations at 400 V AC-1
10000 operations at 415 V AC-1 5000 operations at 690 V AC-3 7500 operations at 415 V AC-3 7500 operations at 400 V AC-3 7500 operations at 690 V AC-1 |
| Direction of incoming supply |
As required
|
| Mounting Method |
Built-in device plug-in technique
Plug-in unit |
| Degree of protection |
IP20 (basic degree of protection, in the operating controls area)
IP20 |
| Degree of protection (IP), front side |
IP66 (with door coupling rotary handle)
IP40 (with insulating surround) |
| Degree of protection (terminations) |
IP00 (terminations, phase isolator and strip terminal)
IP10 (tunnel terminal) |
| Protection against direct contact |
Finger and back-of-hand proof to VDE 0106 part 100
|
| Shock resistance |
20 g (half-sinusoidal shock 20 ms)
|
| Switch off technique |
Magnetic
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Lifespan, mechanical |
20000 operations
|