Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 160A, plug-in module, H2-M160-SVE
| Product Name |
Eaton Moeller series NZM molded case circuit breaker thermo-magnetic
|
| Catalog Number |
113363
|
| Product Length/Depth |
180 mm
|
| Product Height |
245 mm
|
| Product Width |
105 mm
|
| Product Weight |
2.752 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC/EN 60947
IEC |
| Voltage rating |
690 V - 690 V
|
| Rated insulation voltage (Ui) |
1000 V
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Rated operational current |
134 A (400 V AC-3)
|
| Rated short-time withstand current (t = 0.3 s) |
1.9 kA
|
| Rated short-time withstand current (t = 1 s) |
1.9 kA
|
| Amperage Rating |
160 A
|
| Instantaneous current setting (Ii) - min |
1280 A
|
| Instantaneous current setting (Ii) - max |
2240 A
|
| Overload current setting (Ir) - min |
125 A
|
| Overload current setting (Ir) - max |
160 A
|
| Short-circuit release non-delayed setting - min |
1280 A
|
| Short-circuit release non-delayed setting - max |
2240 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
130 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
130 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
37.5 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
5 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
286 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
40 kA
|
| Rated operating power at AC-3, 230 V |
45 kW
|
| Rated operating power at AC-3, 400 V |
75 kW
|
| Short-circuit total breaktime |
< 10 ms
|
| Electrical connection type of main circuit |
Screw connection
|
| Isolation |
500 V AC (between auxiliary contacts and main contacts)
300 V AC (between the auxiliary contacts) |
| Number of operations per hour - max |
120
|
| Handle type |
Rocker lever
|
| Utilization category |
A (IEC/EN 60947-2)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
10000 operations at 415 V AC-1
7500 operations at 690 V AC-1 6500 operations at 400 V AC-3 6500 operations at 415 V AC-3 10000 operations at 400 V AC-1 5000 operations at 690 V AC-3 |
| Direction of incoming supply |
As required
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Rated operational current |
134 A (400 V AC-3)
|
| Rated short-time withstand current (t = 0.3 s) |
1.9 kA
|
| Rated short-time withstand current (t = 1 s) |
1.9 kA
|
| Amperage Rating |
160 A
|
| Instantaneous current setting (Ii) - min |
1280 A
|
| Instantaneous current setting (Ii) - max |
2240 A
|
| Overload current setting (Ir) - min |
125 A
|
| Overload current setting (Ir) - max |
160 A
|
| Short-circuit release non-delayed setting - min |
1280 A
|
| Short-circuit release non-delayed setting - max |
2240 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
130 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
130 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
37.5 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
5 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
286 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
40 kA
|
| Rated operating power at AC-3, 230 V |
45 kW
|
| Rated operating power at AC-3, 400 V |
75 kW
|
| Short-circuit total breaktime |
< 10 ms
|
| Electrical connection type of main circuit |
Screw connection
|
| Isolation |
500 V AC (between auxiliary contacts and main contacts)
300 V AC (between the auxiliary contacts) |
| Number of operations per hour - max |
120
|
| Handle type |
Rocker lever
|
| Utilization category |
A (IEC/EN 60947-2)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
10000 operations at 415 V AC-1
7500 operations at 690 V AC-1 6500 operations at 400 V AC-3 6500 operations at 415 V AC-3 10000 operations at 400 V AC-1 5000 operations at 690 V AC-3 |
| Direction of incoming supply |
As required
|
| Mounting Method |
Built-in device plug-in technique
Plug-in unit |
| Degree of protection |
IP20
IP20 (basic degree of protection, in the operating controls area) |
| Degree of protection (IP), front side |
IP66 (with door coupling rotary handle)
IP40 (with insulating surround) |
| Degree of protection (terminations) |
IP00 (terminations, phase isolator and strip terminal)
IP10 (tunnel terminal) |
| Protection against direct contact |
Finger and back-of-hand proof to VDE 0106 part 100
|
| Shock resistance |
20 g (half-sinusoidal shock 20 ms)
|
| Switch off technique |
Thermomagnetic
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Lifespan, mechanical |
20000 operations
|