Reset
Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 630A, 1000 V, AE630-S1
Product Name |
Eaton Moeller series NZM molded case circuit breaker electronic
|
Catalog Number |
119363
|
Product Length/Depth |
166 mm
|
Product Height |
275 mm
|
Product Width |
140 mm
|
Product Weight |
6.34 kg
|
Compliances |
RoHS conform
|
Certifications |
IEC
|
Voltage rating |
1000 V - 1000 V
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Rated short-time withstand current (t = 0.3 s) |
3.3 kA
|
Rated short-time withstand current (t = 1 s) |
3.3 kA
|
Amperage Rating |
630 A
|
Instantaneous current setting (Ii) - min |
1260 A
|
Instantaneous current setting (Ii) - max |
5040 A
|
Overload current setting (Ir) - min |
315 A
|
Overload current setting (Ir) - max |
630 A
|
Short delay current setting (Isd) - min |
0 A
|
Short delay current setting (Isd) - max |
0 A
|
Short-circuit release non-delayed setting - min |
1260 A
|
Short-circuit release non-delayed setting - max |
5040 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
150 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
150 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
130 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
33 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
9 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 1000 V, 50/60 Hz |
10 kA
|
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
330 kA
|
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
330 kA
|
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
286 kA
|
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
143 kA
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
74 kA
|
Rated short-circuit making capacity Icm at 1000 V, 50/60 Hz |
17 kA
|
Electrical connection type of main circuit |
Screw connection
|
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Utilization category |
A
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
1000 operations at 1000 V AC-1
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Rated short-time withstand current (t = 0.3 s) |
3.3 kA
|
Rated short-time withstand current (t = 1 s) |
3.3 kA
|
Amperage Rating |
630 A
|
Instantaneous current setting (Ii) - min |
1260 A
|
Instantaneous current setting (Ii) - max |
5040 A
|
Overload current setting (Ir) - min |
315 A
|
Overload current setting (Ir) - max |
630 A
|
Short delay current setting (Isd) - min |
0 A
|
Short delay current setting (Isd) - max |
0 A
|
Short-circuit release non-delayed setting - min |
1260 A
|
Short-circuit release non-delayed setting - max |
5040 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
150 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
150 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
130 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
33 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
9 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 1000 V, 50/60 Hz |
10 kA
|
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
330 kA
|
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
330 kA
|
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
286 kA
|
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
143 kA
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
74 kA
|
Rated short-circuit making capacity Icm at 1000 V, 50/60 Hz |
17 kA
|
Electrical connection type of main circuit |
Screw connection
|
Number of operations per hour - max |
60
|
Handle type |
Rocker lever
|
Utilization category |
A
|
Overvoltage category |
III
|
Pollution degree |
3
|
Lifespan, electrical |
1000 operations at 1000 V AC-1
|
Mounting Method |
Built-in device fixed built-in technique
Fixed |
Degree of protection |
IP20
|
Number of auxiliary contacts (change-over contacts) |
0
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Position of connection for main current circuit |
Front side
|
Lifespan, mechanical |
15000 operations
|