代表照片
Download
Product Name |
Eaton Moeller series NZM Undervoltage release
|
Catalog Number |
259659
|
Product Length/Depth |
42 mm
|
Product Height |
90 mm
|
Product Width |
30 mm
|
Product Weight |
0.132 kg
|
Compliances |
IEC
UL/CSA RoHS conform |
Certifications |
IEC60947
UL (File No. E140305) CE marking CSA (File No. 22086) CSA-C22.2 No. 5-09 UL (Category Control Number DIHS) UL listed CSA certified CSA (Class No. 1437-01) UL489 |
Voltage type |
DC
|
Rated control voltage (relay contacts) |
24 V DC
|
Rated control supply voltage |
24 V DC
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Voltage tolerance - min |
.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
1.5 VA (sealing AC)
0.8 W (sealing DC) |
Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
Reaction time |
19 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Rated control voltage (relay contacts) |
24 V DC
|
Rated control supply voltage |
24 V DC
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Voltage tolerance - min |
.85
|
Voltage tolerance - max |
1.1
|
Drop-out voltage of undervoltage release AC/DC - min |
0.35 x Us
|
Drop-out voltage of undervoltage release AC/DC - max |
0.7 x Us
|
Power consumption |
1.5 VA (sealing AC)
0.8 W (sealing DC) |
Pick-up power consumption at AC (undervoltage release) |
1.5 VA
|
Pick-up power consumption at DC (undervoltage release) |
0.8 W
|
Reaction time |
19 ms
|
Minimum command time - min |
10 ms
|
Minimum command time - max |
15 ms
|
Electric connection type |
Screw connection
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
2
|
Connection type |
Contacts 3.23 and 3.24 with separate 3 m connection cables
|