Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 N/O, TVC200: 200 V 50 Hz/200-220 V 60 Hz, AC operation, Screw terminals DILM15-10(TVC200)
| Product Name |
Eaton Moeller® series DILM contactor
|
| Catalog Number |
290069
|
| Product Length/Depth |
75 mm
|
| Product Height |
68 mm
|
| Product Width |
45 mm
|
| Product Weight |
0.24 kg
|
| Certifications |
CSA-C22.2 No. 14-05
VDE 0660 CSA File No.: 012528 UL 508 IEC/EN 60947-4-1 UL Category Control No.: NLDX UL File No.: E29096 IEC/EN 60947 CSA Class No.: 2411-03, 3211-04 UL CE CSA |
| Catalog Notes |
Contacts according to EN 50012
|
| Number of poles |
Three-pole
|
| Application |
Contactors for Motors
|
| Frame size |
FS1
|
| Lifespan, mechanical |
10,000,000 Operations (AC operated)
|
| Operating frequency |
5000 mechanical Operations/h (AC operated)
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Product category |
Contactors
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| Rated impulse withstand voltage (Uimp) |
8000 V AC
|
| Resistance per pole |
2.5 mΩ
|
| Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
| Voltage type |
AC
|
| Shock resistance |
3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
60 °C
|
| Ambient operating temperature (enclosed) - min |
25 °C
|
| Ambient operating temperature (enclosed) - max |
40 °C
|
| Ambient storage temperature - min |
40 °C
|
| Ambient storage temperature - max |
80 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Emitted interference |
According to EN 60947-1
|
| Interference immunity |
According to EN 60947-1
|
| Terminal capacity (flexible with ferrule) |
2 x (0.75 - 2,5) mm²
1 x (0.75 - 2.5) mm² 2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid) |
2 x (0.75 - 2.5) mm²
1 x (0.75 - 4) mm² |
| Terminal capacity (solid/stranded AWG) |
Single 18 - 10, double 18 - 14
|
| Stripping length (main cable) |
10 mm
|
| Stripping length (control circuit cable) |
10 mm
|
| Screw size |
M3.5, Terminal screw
|
| Screwdriver size |
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
2, Terminal screw, Pozidriv screwdriver |
| Tightening torque |
1.2 Nm, Screw terminals
|
| Rated breaking capacity at 220/230 V |
124 A
|
| Rated breaking capacity at 380/400 V |
124 A
|
| Rated breaking capacity at 500 V |
100 A
|
| Rated breaking capacity at 660/690 V |
70 A
|
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
22 A
|
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
15.5 A
|
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
15.5 A
|
| Rated operational current (Ie) at AC-3, 440 V |
15.5 A
|
| Rated operational current (Ie) at AC-3, 500 V |
12.5 A
|
| Rated operational current (Ie) at AC-3, 660 V, 690 V |
9 A
|
| Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V |
7 A
|
| Rated operational current (Ie) at AC-4, 400 V |
7 A
|
| Rated operational current (Ie) at AC-4, 500 V |
6 A
|
| Rated operational current (Ie) at AC-4, 660 V, 690 V |
5 A
|
| Rated operational current (Ie) at DC-1, 60 V |
20 A
|
| Rated operational current (Ie) at DC-1, 110 V |
20 A
|