The Menvier MF200 and MF400 range of conventional control panels offer a competitive solution for smaller installations. Easy to install and operate, the panels are designed to provide fire detection and alarm facilities in buildings where the basic elements of protection to meet BS5839 are required.

Available as either a 2 zone or 4 zone panel with up to 20 detectors per zone can be connected. This range of Menvier control panels are conveniently supplied complete with end of line devices and batteries offering 24 hours standby as standard, with the option of 72 hours on the 4 zone version. 

Discover our fire systems and devices, and voice alarm product ranges

Specifications

This product has been discontinued and is no longer available. For technical support contact FireTechSupport@Eaton.com.

PRODUCT CODES

Conventional 2 Zone Control Panel MF200
Conventional 4 Zone Control Panel MF400
Conventional 4 Zone Control Panel (72 hour standby) MF400-72

TECHNICAL SPECIFICATIONS

Code

MF200

MF400

Description

2 zone control panel

4 zone control panel

Standards

EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996

EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996

Specification

Number of Zones

2

4

Detectors per Zone

20

20

Number of Alarm Lines

2

2

Alarm Circuit Load

375mA per circuit. 750mA total

375mA per circuit. 750mA total

End of Line Devices

Detection circuits: 22KΩ resistor

Alarm lines: 22KΩ resistor

Detection circuits: 22KΩ resistor

Alarm lines: 22KΩ resistor

Auxiliary Fire Signal Output

24V dc pull to 0V. Max 10mA

24V dc pull to 0V. Max 10mA

Auxiliary Fault Output

24V dc pull to 0V. Max 10mA

24V dc pull to 0V. Max 10mA

Auxiliary dc Output

24V dc fused. 32mA

(up to 100mA at the expense of alarm load)

24V dc fused. 32mA

(up to 100mA at the expense of alarm load)

Mains Input Voltage

240V ac +10%-15%

240V ac +10%-15%

System Operating Voltage

24V dc

24V dc

Standby Duration

24 hours

24 hours (72 hours on MF400-72)

Battery

1 x 4Ah sealed lead acid battery

1 x 4Ah sealed lead acid battery

(1 x 7Ah on MF400-72)

Recharge Period

48 hours (80% in 24 hours)

48 hours (80% in 24 hours)

Environmental

Operating Temperature

-5°C to +40°C

-5°C to +40°C

Humidity (Non Condensing)

0 to 75% RH

0 to 75% RH

Physical

Construction

ABS/Polycarbonate housing. Steel back box.

ABS/Polycarbonate housing. Steel back box.

Dimensions (H x W x D)

300mm x 300mm x 74mm 4.8kg (6.0kg on MF400-72)

300mm x 300mm x 74mm 4.8kg (6.0kg on MF400-72)

Weight

4.8kg

4.8kg (6.0kg on MF400-72)

Ingress Protection

IP30

IP30

Cable entries

Top: 10 x 20mm conduit entries

Bottom: 1 x 20mm conduit entry (mains cable)

Back: 1 x mains cable entry slot

Top: 10 x 20mm conduit entries

Bottom: 1 x 20mm conduit entry (mains cable)

Back: 1 x mains cable entry slot 