Eaton Moeller® series Rapid Link - Speed controllers, 8.5 A, 4 kW, Sensor input 4, 230/277 V AC, AS-Interface®, S-7.4 for 31 modules, HAN Q4/2, with manual override switch, with fan
| Product Name |
Eaton Rapid Link Speed controller
|
| Catalog Number |
198854
|
| EAN |
4015081969128
|
| Product Length/Depth |
195 mm
|
| Product Height |
270 mm
|
| Product Width |
220 mm
|
| Product Weight |
3.77 kg
|
| Certifications |
RoHS
UL approval IEC/EN 61800-5-1 UL 61800-5-1 CE |
| Catalog Notes |
|
| Model Code |
RASP5-8402A31-412R001S1
|
| Features |
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App) Parameterization: Fieldbus Parameterization: Keypad Internal and on heat sink, temperature-controlled Fan Diagnostics and reset on device and via AS-Interface |
| Fitted with: |
Selector switch (Positions: REV - OFF - FWD)
PTC thermistor monitoring PC connection Key switch position AUTO Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Thermo-click with safe isolation Key switch position OFF/RESET Fan Control unit Internal DC link IGBT inverter Manual override switch Key switch position HAND |
| Functions |
For actuation of motors with mechanical brake
3 fixed speeds 1 potentiometer speed |
| Degree of protection |
NEMA 12
IP65 |
| Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
| Overvoltage category |
III
|
| Product category |
Speed controller
|
| Product category |
Speed controller
|
| Protocol |
ASI
AS-Interface profile cable: S-7.4 for 31 modules |
| Radio interference class |
C1: for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. |
| Rated impulse withstand voltage (Uimp) |
2000 V
|
| System configuration type |
Phase-earthed AC supply systems are not permitted.
AC voltage Center-point earthed star network (TN-S network) |
| Mounting position |
Vertical
|
| Shock resistance |
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft
|
| Vibration |
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6 Resistance: 6 Hz, Amplitude 0.15 mm Resistance: 57 Hz, Amplitude transition frequency on acceleration |
| Altitude |
Above 1000 m with 1 % performance reduction per 100 m
Max. 2000 m |
| Ambient operating temperature - min |
-10 °C
|
| Ambient operating temperature - max |
40 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Ambient storage temperature - max |
70 °C
|
| Climatic proofing |
< 95 %, no condensation
In accordance with IEC/EN 50178 |
| Current limitation |
0.8 - 8.5 A, motor, main circuit
Adjustable, motor, main circuit |
| Delay time |
< 10 ms, Off-delay
< 10 ms, On-delay |
| Efficiency |
98 % (η)
|
| Heat dissipation at current/speed |
51.6 W at 25% current and 0% speed
53.8 W at 25% current and 50% speed 60.9 W at 50% current and 0% speed 64 W at 50% current and 90% speed 65.4 W at 50% current and 50% speed 85.1 W at 100% current and 0% speed 94 W at 100% current and 50% speed 95.3 W at 100% current and 90% speed |
| Input current ILN at 150% overload |
7.8 A
|
| Leakage current at ground IPE - max |
3.5 mA
|
| Mains current distortion |
120 %
|
| Mains switch-on frequency |
Maximum of one time every 60 seconds
|
| Mains voltage - max |
480 V
|
| Mains voltage - min |
380 V
|
| Mains voltage tolerance |
380 - 480 V (-10 %/+10 %, at 50/60 Hz)
|
| Operating mode |
U/f control
Sensorless vector control (SLV) BLDC motors PM and LSPM motors Synchronous reluctance motors |
| Output frequency - max |
500 Hz
|
| Output frequency - min |
0 Hz
|
| Overload current |
For 60 s every 600 s
At 40 °C |
| Overload current IL at 150% overload |
12.7 A
|
| Rated frequency - max |
66 Hz
|
| Rated frequency - min |
45 Hz
|
| Rated operational current (Ie) |
8.5 A at 150% overload (at an operating frequency of 8 kHz and an ambient air temperature of +40 °C)
|
| Rated operational power at 380/400 V, 50 Hz, 3-phase |
4 kW
|
| Rated operational voltage |
400 V AC, 3-phase
480 V AC, 3-phase |
| Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
| Starting current - max |
200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section
|
| Supply frequency |
50/60 Hz
|
| Switching frequency |
8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit
|
| Assigned motor power at 460/480 V, 60 Hz, 3-phase |
5 HP
|
| Braking current |
≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
|
| Braking torque |
≤ 30 % (I/Ie)
Adjustable to 100 % (I/Ie), DC - Main circuit |
| Braking voltage |
230/277 V AC -15 % / +10 %, Actuator for external motor brake
|
| Rated conditional short-circuit current (Iq) |
10 kA
|
| Short-circuit protection (external output circuits) |
Type 1 coordination via the power bus' feeder unit, Main circuit
|
| Rated control voltage (Uc) |
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
230/277 V AC (external brake 50/60 Hz) |
| Communication interface |
AS-Interface
|
| Connection |
Plug type: HAN Q4/2
|
| Interfaces |
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®) Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA |
| Cable length |
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length C3 ≤ 25 m, maximum motor cable length |
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|