Eaton XN-322 Serial interface module, data from two SSI encoders via RS422, 32 bits / 125 kHz, 250kHz, 500kHz, 1MHz
| Product Name |
Eaton XN-322 Interface module
|
| Catalog Number |
178773
|
| EAN |
7640130098374
|
| Product Length/Depth |
104.2 mm
|
| Product Height |
16.8 mm
|
| Product Width |
80.3 mm
|
| Product Weight |
0.046 kg
|
| Certifications |
UL File No.: E135462
cULus CE EN 61131-2 EN 61000-6-2 EN 61000-6-4 UL508 CSA-C22.2 No. 142-M |
| Features |
Fieldbus connection over separate bus coupler possible
|
| Functions |
Binary/gray coding (Absolute encoder)
|
| Channels |
2, Transmission channel CL, D, Digital inputs, Absolute encoder
|
| Current consumption |
27 mA (typ.), for +24 V, Power supply - Input
|
| Degree of protection |
IP20
|
| Mounting method |
Rail mounting possible
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Resolution |
32 Bit
|
| Type |
|
| Used with |
XN-312-…
XN300 |
| Voltage type |
DC
|
| Height of fall (IEC/EN 60068-2-32) - max |
1 m
|
| Mounting position |
Horizontal
|
| Shock resistance |
15 g, Mechanical, Half-sinusoidal shock 11 ms, 18 Impacts
|
| Vibration resistance |
5 - 8.4 / 8.4 -150 Hz, 3,5 mm / 1 g
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Ambient operating temperature - min |
0 °C
|
| Ambient operating temperature - max |
60 °C
|
| Ambient storage temperature - min |
-20 °C
|
| Ambient storage temperature - max |
85 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2 |
| Environmental conditions |
Condensation: prevent with appropriate measures
|
| Relative humidity |
0 - 95 % (non-condensing)
|
| Air discharge |
8 kV
|
| Burst impulse |
2 kV, Supply cable
1 kV, Signal cable |
| Contact discharge |
4 kV
|
| Electromagnetic fields |
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3) 3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3) |
| Emitted interference |
47 dB (at 230 - 1000 MHz, Class A, radiated, high frequency)
40 dB (at 30 - 230 MHz, Class A, radiated, high frequency) |
| Radiated RFI |
10 V
|
| Surge rating |
1 kV, Signal cable, unbalanced, EMC
0.5/0.5 kV, Supply cable, balanced/unbalanced), EMC |
| Voltage dips |
Voltage dips: 10 ms/Voltage fluctuations: Yes
|
| Terminal capacity |
0.2 - 1.5 mm², flexible without ferrule, H07V-K
0.2 - 1.5 mm², solid, H07V-U 24 - 16 AWG 0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) 0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
| Gauge pin |
A1 (according to IEC/EN 60947-1)
|
| Stripping length (main cable) |
10 mm
|
| Insulating material group |
I
|
| Rated operational voltage |
160 V (terminations)
|
| Supply voltage at AC, 50 Hz - min |
0 V
|
| Supply voltage at AC, 50 Hz - max |
0 V
|
| Supply voltage at DC - min |
18 V
|
| Supply voltage at DC - max |
30 V
|
| Bus termination |
Internal, Digital inputs, Absolute encoder
|
| Connection type |
RS422, Digital inputs, Absolute encoder
Push-in spring-cage terminal (plug-in connection), Connection design in TOP direction |
| Data transfer rate |
Parameterizable, Digital inputs
|
| Protocol |
Other bus systems
|
| Load current |
Not specified by plug manufacturer
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Potential isolation |
Digital inputs, Absolute encoder: no
|
| Equipment heat dissipation, current-dependent Pvid |
1 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
1.06 W
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|