With a customisable and flexible design, Pow-R-Way III busway is the preferred means of connecting electrical equipment to maximise power distribution system performance. Its ease of use and speed of installation provides an efficient solution for even the most challenging layout requirements, compared to traditional cabling conduit solutions.

Watch this video to find out how to measure the final field-fit piece.

Continuous current rating
Up to 5000A Cu
Up to 4000A Al
System voltage rating
Up to 600V
Interrupting rating
Up to 200kA

Core features

  • Lightweight and compact design allows easy installation
  • Housing is combined in a true sandwich design in both plug-in and feeder busway, contributing to improved coordination and high short-circuit ratings
  • Epoxy insulation process ensures optimum conductor and system protection
  • All bus plugs are polarised to prevent improper installation
  • Having only one or two conductors per phase, the Pow-R-Bridge joint design makes the voltage drop much lower than that associated with cable, allowing a more efficient use of energy

Busway infrared joint cover

This new cover allows safe and efficient temperature reading of busway joints.

The differences between indoor, sprinkler-proof and outdoor-rated busway

Watch the video to find out about the applicable conditions for busway installation.

Calculate the savings

Find out how busway reduces installation costs compared to traditional cable management systems

Read case study

Eaton’s busway enables smooth operations and new levels of data centre flexibility

Infrared thermography in busway

Discover what infrared thermography is and how it works

Find out how to measure the final field-fit piece

Watch the video 

Eaton's busway solutions

Eaton’s comprehensive portfolio of busway solutions offers endless possibilities for meeting today’s ever-changing power requirements

Find out about the busway installation process

Watch the video 

    You may also be interested in

    Specifications

    Ratings

    Continuous current

    Up to 5000A Cu

    Up to 4000A Al

    System voltage
    240–600 V

    Short circuit tolerance

    Up to 200 kA

    Standards

    Third-party approval/recognition

    UL 857 and CSA C22.2 no. 27 listed

    Seismic qualification
    CBC, IBC

    Devices

    Maintenance solution

    IR bridge joint window

    Enclosure

    Enclosure type

    Indoor, outdoor, sprinkler-proof

    Construction
    Aluminium housing, feeder, plug-in
    Plug-in/tap-off separation
    610mm/24”