Eaton Moeller® series M22 Indicator light, RMQ-Titan, Extended, conical, Blue
Product Name |
Eaton Moeller® series M22 Indicator light
|
Catalog Number |
216782
|
EAN |
4015082167820
|
Product Length/Depth |
30 mm
|
Product Height |
38 mm
|
Product Width |
30 mm
|
Product Weight |
0.007 kg
|
Certifications |
CSA Class No.: 3211-03
CSA-C22.2 No. 94-91 CE CSA CSA-C22.2 No. 14-05 IEC/EN 60947-5 UL 508 VDE 0660 UL CSA File No.: 012528 IEC/EN 60947 UL Category Control No.: NKCR UL File No.: E29184 |
Type |
Indicator lights
|
10.10 Temperature rise |
Not applicable.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Front ring
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Connection to SmartWire-DT |
Yes
With SWD-RMQ connections |
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Bezel color |
Chrome
|
Shock resistance |
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27 |
Bezel material |
Other
|
Terminal capacity |
0.5 - 1.5 mm², solid
0.5 - 1.5 mm², stranded |
Lens color |
Blue
|
Design |
Extended, conical
|
Mounting position |
As required
|
Overvoltage category |
III
|
Degree of protection |
NEMA 4X, 13
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Force for positive opening - min |
0 N
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Opening diameter |
22.5 mm
|
Opening height |
22.5 mm
|
Rated insulation voltage (Ui) |
250 V
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Suitable for number of built-in signal lights |
1
|
Width opening |
0 mm
|
Product category |
RMQ-Titan
|
Size |
Front diameter: 29.7 mm
|
Degree of protection (front side) |
IP67/IP69K
|
Lens type |
Round
High |