Eaton DC1 Variable frequency drive, 115 V AC, single-phase, 5.8 A, 1.1 kW, IP66/NEMA 4X, Brake chopper, 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, FS2
Product Name |
Eaton DC1 Variable frequency drive
|
Catalog Number |
199398
|
EAN |
4015081977871
|
Product Length/Depth |
182 mm
|
Product Height |
257 mm
|
Product Width |
188 mm
|
Product Weight |
3.5 kg
|
Certifications |
UL Listed
UL File No.: E172143 Certified by UL for use in Canada UL report applies to both US and Canada UkrSEPRO CSA-C22.2 No. 14 IEC/EN61800-5 UL UL 508C EAC RoHS, ISO 9001 CUL IEC/EN 61800-2 IEC/EN 61800-3 RCM CE CE marking UL Category Control No.: NMMS, NMMS7 IEC/EN 61800-5-1 |
Features |
Parameterization: drivesConnect
Parameterization: Fieldbus Parameterization: Keypad Parameterization: drivesConnect mobile (App) |
Fitted with: |
Brake chopper
Local controls Internal DC link PC connection Additional PCB protection IGBT inverter 7-digital display assembly Breaking resistance UV resistance Control unit |
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Connection to SmartWire-DT |
No
|
Operating mode |
Sensorless vector control (SLV)
Synchronous reluctance motors Speed control with slip compensation PM motors U/f control BLDC motors |
Frame size |
FS2
|
Altitude |
Above 1000 m with 1 % derating per 100 m
Max. 4000 m |
Application in domestic and commercial area permitted |
Yes
|
Mains switch-on frequency |
Maximum of one time every 30 seconds
|
Ambient operating temperature - max |
40 °C
|
Ambient operating temperature - min |
-20 °C
|
Mains voltage - max |
115 V
|
Output voltage - max |
250 V
|
Rated operational power at 220/230 V, 50 Hz, 3-phase |
1.1 kW
|
Relative symmetric net frequency tolerance |
10 %
|
Relative symmetric net voltage tolerance |
10 %
|
Ambient storage temperature - max |
60 °C
|
Ambient storage temperature - min |
-40 °C
|
Application in industrial area permitted |
Yes
|
Product category |
Variable frequency drives
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
Switch-on threshold for the braking transistor |
390 VDC
|
Voltage rating - max |
120 V
|
Mounting position |
Vertical
|
Communication interface |
SmartWire-DT, optional
Modbus RTU, built in OP-Bus (RS485), built in CANopen®, built in |
Converter type |
U converter
|
Degree of protection |
NEMA 4X
IP66 |
Assigned motor power at 230/240 V, 60 Hz, 3-phase |
1.5 HP
|
Braking resistance |
100 Ω
|
Input current ILN at 150% overload |
21.9 A
|
Assigned motor current IM at 230 V, 50 Hz, 150% overload |
4.6 A
|
Protocol |
Other bus systems
MODBUS EtherNet/IP CAN |
Overload current IL at 150% overload |
8.7 A
|
Rated frequency - max |
62 Hz
|
Rated frequency - min |
48 Hz
|
System configuration type |
AC supply systems with earthed center point
|
Braking torque |
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit Max. 100 % of rated operational current Ie with external braking resistor - Main circuit |
Cable length |
150 m, unscreened, maximum permissible cable length
100 m, screened, maximum permissible cable length 300 m, unscreened, with motor choke, maximum permissible, Motor feeder 200 m, screened, with motor choke, maximum permissible cable length |
Functions |
4-quadrant operation possible
|
Output voltage (U2) |
230 V AC, 3-phase
|
Number of inputs (analog) |
2
|
Number of inputs (digital) |
4
|
Radio interference class |
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
|
Number of outputs (digital) |
1
|
Starting current - max |
175 % IH
|
Number of phases (input) |
1
|
Number of relay outputs |
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
|
Number of phases (output) |
3
|
Power consumption |
44 W
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Efficiency |
97 % (η)
|
Supply frequency |
50/60 Hz
|
Leakage current at ground IPE - max |
4.8 mA
|
Mains voltage - min |
110 V
|
Nominal output current I2N |
5.8 A
|
Number of HW-interfaces (industrial ethernet) |
0
|
Number of HW-interfaces (other) |
0
|
Number of HW-interfaces (parallel) |
0
|
Number of HW-interfaces (RS-232) |
0
|
Number of HW-interfaces (RS-422) |
0
|
Number of HW-interfaces (RS-485) |
1
|
Number of HW-interfaces (serial TTY) |
0
|
Number of HW-interfaces (USB) |
0
|
Number of interfaces (PROFINET) |
0
|
Number of outputs (analog) |
1
|
Output at linear load at rated output voltage - max |
1.1 kW
|
Output at quadratic load at rated output voltage - max |
1.1 kW
|
Output frequency - max |
500 Hz
|
Output frequency - min |
0 Hz
|
Suitable for |
Branch circuits, (UL/CSA)
|
Switching frequency |
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
|
Rated operational current (Ie) |
5.8 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
|
Rated operational voltage |
115 V AC, 1-phase
|
Short-circuit protection rating |
35 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|