Download document () of 20
Surge protection

Eaton SPC series

Eaton’s SPC series is a configurable surge protective device providing safe, robust downstream protection for critical equipment in commercial and light industrial applications. Featuring a compact, NEMA 4X enclosure and Eaton’s proprietary tri-colored LED indicator lights, the SPC offers configurable options, including EMI/RFI filtering, audible alarm and form C contacts.

Understand the true health of your surge protection

Eaton’s proprietary “low protection” yellow light enables the SPC to display three phases of LED indicator lights, giving you at-a-glance information on the status of your surge protection.

Low cost filtering option

Surge protective devices with filtering don’t have to be expensive. Get the protection of EMI/RFI filtering in an affordable, compact footprint.

Made for any environment

A compact UV-resistant NEMA 4x enclosure means this surge protection device can be using in indoor or outdoor applications

When flushmounting is a “need to have,” not a “want to have”

All possible configurations of the Eaton SPC device are flushmountable, so you don’t have to choose between the features and mounting style.

Related surge videos

    Specifications
    Highlight differences
    Show only differences
    Hide blank features

    Product specifications

    PEAK SURGE CURRENT CAPACITY RATINGS AVAILABLE

    50, 80, 100, 120, 150, 160, 200 kA per phase

    NOMINAL DISCHARGE CURRENT (LN)

    20 kA

    SHORT-CIRCUIT CURRENT RATING (SCCR)

    200 kA

    INPUT POWER FREQUENCY

    50/60 Hz

    PORTS

    1

    OPERATING TEMPERATURE

    -40°C to +60°C

    (-40°F to +140°F)

    STORAGE TEMPERATURE

    -40°C to +60°C

    (-40°F to +140°F)

    OPERATING HUMIDITY

    5% to 95%, noncondensing

    OPERATING ALTITUDE

    Up to 2000M (6561 ft)

    AGENCY CERTIFICATION/LISTING

    UL 1449 4th edition

    UL 1283 7th edition

    CSA C22.2 No. 269.1-14 for Type 1 SPD

    CSA C22.2 No. 269.2-13 for Type 2 SPD

    CSA C22.2 No. 8-13 for EMI filter

    DURABILITY REPETITIVE STRIKE TEST

    Passed 12,000 strikes to ANSI/IEEE C62.41 (20 kV, 10 kA) Category C waveform

    SPD TYPE

    UL 1449 4th edition and CSA Type 1 and Type 2 SPD (dependent on feature options)

    ENCLOSURE RATING

    NEMA 4X enclosure

    FORM C RELAY CONTACT RATINGS

    2 A at 30 Vdc or 250 Vac

    FORM C RELAY CONTACT LOGIC

    Power ON, normal state: No contact=open, NC contact=closed

    Power OFF, fault state: No contact=closed, NC contact=open

    EMI/RFI FILTERING ATTENUATION

    Up to 40 dB from 10 kHz ro 100 MHz

    ROHS COMPLIANT

    Yes

    WARRANTY

    5 years standard, 10 years with product registration

    SINGLE-PHASE (2W + G)
    SPLIT-PHASE (3W + G)
    THREE-PHASE WYE (4W + G)
    THREE-PHASE DELTA (3W + G)
    THREE-PHASE HIGH LEG DELTA (4W + G)
    SYSTEM VOLTAGES AVAILABLE (VAC)
    SINGLE-PHASE (2W + G)

    120

    240

    277

    480

    SPLIT-PHASE (3W + G)

    120/240

    THREE-PHASE WYE (4W + G)

    120/208

    240/415

    277/480

    347/600

    THREE-PHASE DELTA (3W + G)

    240

    480

    600

    THREE-PHASE HIGH LEG DELTA (4W + G)

    240

    PROTECTION MODES
    SINGLE-PHASE (2W + G)

    L-N

    N-G

    L-G

    SPLIT-PHASE (3W + G)

    L-N

    N-G

    L-G

    L-L

    THREE-PHASE WYE (4W + G)

    L-N

    N-G

    L-G

    L-L

    THREE-PHASE DELTA (3W + G)

    L-G

    L-L

    THREE-PHASE HIGH LEG DELTA (4W + G)

    L-G

    L-L

    Maximum continuous operating voltage (MCOV)

    120N

    150 L-N, 150 L-G, 150 N-G

    240N, 277N

    320 L-N, 320 L-G, 320 N-G

    480N

    550 L-N, 550 L-G, 550 N-G

    240S, 208Y

    150 L-N, 150 L-G, 150 N-G, 300 L-L

    240H

    150 L-N, 150 L-G, 150 N-G, 300 L-L, 470 H-L, 320 H-N, 320 H-G

    415Y, 480Y

    320 L-N, 320 L-G, 320 N-G, 640 L-L

    600Y

    420 L-N, 420 L-G, 420 N-G, 840 L-L

    240D

    320 L-G, 300 L-L

    480D

    550 L-G, 640 L-L

    600D

    840 L-G, 840 L-L

    Download Links