Eaton Moeller® series E53 Proximity switch, capacitive, Sn=35mm, 1N/O, 2L, 20-250VAC, M34, insulated material, line 2m
Product Name |
Eaton Moeller® series E53 Proximity switch
|
Catalog Number |
134781
|
Model Code |
E53KAL34A2E
|
EAN |
4015081316335
|
Product Length/Depth |
152.4 mm
|
Product Height |
44.45 mm
|
Product Width |
152.4 mm
|
Product Weight |
0.23 kg
|
Certifications |
CE
IEC/EN 60947-5-2 |
Type |
Capacitive sensor
|
Electric connection type |
Cable
|
Enclosure material finishing |
Other
|
Fitted with: |
Status indication
|
Actuation type |
Other
|
Enclosure material |
Plastic
|
Enclosure type |
Cylinder plain
|
Category (EN 954-1) |
B
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Voltage type |
AC
|
Mounting method |
Non-flush mounting
|
Material |
Insulated material
|
Connection type |
2 m connection cable
2-wire |
Installation type |
Not flat
|
Degree of protection |
NEMA 12
NEMA 13 IP65 NEMA 4 |
Interface type |
None
|
LED indicator |
Status indication of Switching state: Red LED
|
Switch function type |
Normally open contact
|
Load current |
5 - 300 mA (Ie)
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
20 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated switching distance (Sn) |
35 mm
|
Repeatability |
10 %
|
Sensor height |
0 mm
|
Sensor length |
80 mm
|
Supply voltage - max |
250 V
|
Supply voltage - min |
20 V
|
Switching hysteresis of Sn |
20 %
|
Voltage drop (Ud) |
9 V
|
Voltage rating - max |
250 V
|
Width sensor |
0 mm
|
Product category |
E53 Capacitive Series
|
Operational current (Ib) |
< 2.5 mA (in the switched state at 24 V DC)
|
Rated short-time withstand current |
5 A (10 ms, 5 Hz)
|
Residual current |
2.5 mA (through the load in the blocked state at 230 V AC and 24 V DC)
|
Residual ripple |
10 % (Uₑ)
|
Shock resistance |
30 g, Mechanical, Shock duration 11 ms
|
Supply frequency |
50 Hz, Input, min. Range
60 Hz, Input, max. Range |
Switching frequency |
15 Hz
|
Switching output type |
Two-wire
|
Temperature drift of sn |
10 %
|
Safety performance level (EN ISO 13849-1) |
None
|
SIL (IEC 61508) |
None
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Diameter sensor |
34 mm
|
Number of contact energized outputs with signalling function |
0
|
Number of contacts (normally open contacts) |
1
|
Number of outputs (protected contact energized) |
0
|
Number of outputs (protected semiconductor) |
0
|
Number of outputs (semiconductor with signaling function) |
1
|
Output current at protected output - max |
0 mA
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
250 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
20 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
250 V
|