Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 11 kW, 1 N/O, 1 NC, RDC 24: 24 - 27 V DC, DC operation, Push in terminals
Product Name |
Eaton Moeller® series DILM contactor
|
Catalog Number |
199288
|
EAN |
4015081973729
|
Product Length/Depth |
115 mm
|
Product Height |
85 mm
|
Product Width |
45 mm
|
Product Weight |
0.546 kg
|
Certifications |
VDE 0660
IEC/EN 60947 UL Listed CSA certified UL Category Control No.: NLDX CE marking UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 CSA File No.: 012528 |
Catalog Notes |
Also tested according to AC-3e.
|
Number of poles |
Three-pole
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Mirror contact
|
Operating frequency |
5000 mechanical Operations/h (DC operated)
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Connection to SmartWire-DT |
In conjunction with DIL-SWD SmartWire DT contactor module
Yes |
Rated impulse withstand voltage (Uimp) |
8000 V AC
|
Utilization category |
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
Connection |
Push in terminals
|
Frame size |
FS2
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Ambient operating temperature (enclosed) - min |
-25 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
-40 °C
|
Assigned motor power at 115/120 V, 60 Hz, 1-phase |
2 HP
|
Assigned motor power at 200/208 V, 60 Hz, 3-phase |
7.5 HP
|
Assigned motor power at 230/240 V, 60 Hz, 1-phase |
5 HP
|
Assigned motor power at 230/240 V, 60 Hz, 3-phase |
10 HP
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
15 HP
|
Assigned motor power at 575/600 V, 60 Hz, 3-phase |
20 HP
|
Conventional thermal current Ith (1-pole, enclosed) |
90 A
|
Conventional thermal current Ith (3-pole, enclosed) |
36 A
|
Conventional thermal current Ith at 55°C (3-pole, open) |
42 A
|
Conventional thermal current Ith of main contacts (1-pole, open) |
100 A
|
Heat dissipation capacity Pdiss |
0 W
|
Switching time (DC operated, make contacts, closing delay) - max |
47 ms
|
Switching time (DC operated, make contacts, opening delay) - max |
30 ms
|
Application |
Contactors for Motors
|
Product category |
Contactors
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Arcing time |
10 ms
|
Electrical connection type of main circuit |
Push-in connection
|
Screwdriver size |
3 x 0.5 mm, Terminal screw
3.0 x 0.5 mm, Terminal screw |
Voltage type |
DC
|
Degree of protection |
IP20
|
Number of auxiliary contacts (normally closed contacts) |
1
|
Number of auxiliary contacts (normally open contacts) |
1
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally closed) as main contact |
0
|
Number of contacts (normally open contacts) |
1
|
Number of main contacts (normally open contact) |
3
|
Power consumption (pick-up) at DC |
12 W
|
Power consumption (sealing) at DC |
0.9 W
|
Rated breaking capacity at 220/230 V |
250 A
|
Rated breaking capacity at 380/400 V |
250 A
|
Rated breaking capacity at 500 V |
250 A
|
Rated breaking capacity at 660/690 V |
150 A
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Overvoltage category |
III
|
Duty factor |
100 %
|
Emitted interference |
According to EN 60947-1
|
Interference immunity |
According to EN 60947-1
|
Lifespan, mechanical |
10,000,000 Operations (DC operated)
|
Pick-up voltage |
24 - 27 V DC (RDC 24)
0.7 - 1.2 V DC x Uc 0.7 - 1.2 V DC x Us |
Safe isolation |
400 V AC, Between coil and contacts, According to EN 61140
400 V AC, Between the contacts, According to EN 61140 |
Terminal capacity (flexible with unisolated ferrule) |
1 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.5 - 2.5) mm², Control circuit cables 2 x (0.5 - 2.5) mm², Control circuit cables 1 x (1 - 6) mm², Main cables 2 x (1 - 6) mm², Main cables |
Terminal capacity (flexible with ultrasonic welded cable end) |
1 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.5 - 2.5) mm², Control circuit cables 2 x (0.5 - 2.5) mm², Control circuit cables 1 x (1 - 10) mm², Main cables 2 x (1 - 6) mm², Main cables |
Terminal capacity (flexible with ferrule) |
2 x (1 - 4) mm²
1 x (1 - 6) mm² 2 x (0.5 - 1.5) mm², Main cables 1 x (0.5 - 1.5) mm², Control circuit cables |
Shock resistance |
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 6.5 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 8 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 2 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
Terminal capacity (solid) |
1 x (1 - 6) mm²
2 x (1 - 6) mm² 1 x (0.5 - 0.25) mm² 2 x (0.5 - 2.5) mm², Control circuit cables |
Terminal capacity (solid/stranded AWG) |
18 - 8, Main cables
20 - 14 |
Terminal capacity (flexible) |
1 x (0.5 - 2.5) mm²
1 x (1 - 10) mm² 2 x (0.5 - 2.5) mm² 2 x (1-6) mm² |
Rated control supply voltage (Us) at DC - max |
27 V
|
Rated control supply voltage (Us) at DC - min |
27 V
|
Rated insulation voltage (Ui) |
690 V
|
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) |
350 A
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
45 A
|
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V |
25 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
25 A
|
Rated operational current (Ie) at AC-3, 440 V |
25 A
|
Rated operational current (Ie) at AC-3, 500 V |
25 A
|
Rated operational current (Ie) at AC-3, 660 V, 690 V |
15 A
|
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V |
13 A
|
Rated operational current (Ie) at AC-4, 400 V |
13 A
|
Rated operational current (Ie) at AC-4, 440 V |
13 A
|
Rated operational current (Ie) at AC-4, 500 V |
13 A
|
Rated operational current (Ie) at AC-4, 660 V, 690 V |
10 A
|
Rated operational current (Ie) at DC-1, 110 V |
40 A
|
Rated operational current (Ie) at DC-1, 220 V |
40 A
|
Rated operational current (Ie) at DC-1, 60 V |
40 A
|
Rated operational power at AC-3, 240 V, 50 Hz |
8.5 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
11 kW
|
Rated operational power at AC-3, 415 V, 50 Hz |
14.5 kW
|
Rated operational power at AC-4, 220/230 V, 50 Hz |
3.5 kW
|
Rated operational power at AC-4, 240 V, 50 Hz |
4 kW
|
Rated operational power at AC-4, 380/400 V, 50 Hz |
6 kW
|
Rated operational power at AC-4, 415 V, 50 Hz |
6.5 kW
|
Rated operational power at AC-4, 440 V, 50 Hz |
7 kW
|
Rated operational power at AC-4, 500 V, 50 Hz |
8 kW
|
Rated operational power at AC-4, 660/690 V, 50 Hz |
8.5 kW
|
Rated operational power (NEMA) |
0 kW
|
Rated operational voltage (Ue) at AC - max |
690 V
|
Short-circuit current rating (high fault at 480 V) |
65 kA, CB, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA) |
Short-circuit protection rating (type 1 coordination) at 400 V |
100 A gG/gL
|
Suitable for |
Also motors with efficiency class IE3
|
Short-circuit protection rating (type 1 coordination) at 690 V |
50 A gG/gL
|
Short-circuit protection rating (type 2 coordination) at 400 V |
35 A gG/gL
|
Short-circuit protection rating (type 2 coordination) at 690 V |
35 A gG/gL
|
Operating voltage at AC, 50 Hz - min |
24 V
|
Operating voltage at AC, 50 Hz - max |
690 V
|
Operating voltage at AC, 60 Hz - min |
24 V
|
Operating voltage at AC, 60 Hz - max |
690 V
|