Eaton DC1 Variable frequency drive, 230 V AC, 1-phase, 4.3 A, 0.37 kW, IP66/NEMA 4X, Radio interference suppression filter, 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, FS1
Product Name |
Eaton DC1 Variable frequency drive
|
Catalog Number |
199388
|
EAN |
4015081977772
|
Product Length/Depth |
162 mm
|
Product Height |
232 mm
|
Product Width |
161 mm
|
Product Weight |
2.5 kg
|
Certifications |
CUL
EAC CE UkrSEPRO UL File No.: E172143 CE marking IEC/EN 61800-2 IEC/EN 61800-3 UL 508C IEC/EN 61800-5-1 UL Category Control No.: NMMS, NMMS7 UL UL Listed UL report applies to both US and Canada RCM CSA-C22.2 No. 14 IEC/EN61800-5 RoHS, ISO 9001 Certified by UL for use in Canada |
Features |
Parameterization: Fieldbus
Parameterization: drivesConnect Parameterization: Keypad Parameterization: drivesConnect mobile (App) |
Fitted with: |
Local controls
UV resistance 7-digital display assembly PC connection Radio interference suppression filter Control unit Additional PCB protection IGBT inverter Internal DC link |
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Connection to SmartWire-DT |
No
|
Operating mode |
U/f control
PM motors Sensorless vector control (SLV) BLDC motors Synchronous reluctance motors Speed control with slip compensation |
Frame size |
FS1
|
Altitude |
Max. 4000 m
Above 1000 m with 1 % derating per 100 m |
Application in domestic and commercial area permitted |
Yes
|
Mains switch-on frequency |
Maximum of one time every 30 seconds
|
Ambient operating temperature - max |
40 °C
|
Ambient operating temperature - min |
-20 °C
|
Mains voltage - max |
240 V
|
Output voltage - max |
250 V
|
Relative symmetric net frequency tolerance |
10 %
|
Relative symmetric net voltage tolerance |
10 %
|
Ambient storage temperature - max |
60 °C
|
Ambient storage temperature - min |
-40 °C
|
Apparent power at 230 V |
0.99 kVA
|
Apparent power at 240 V |
1.03 kVA
|
Application in industrial area permitted |
Yes
|
Product category |
Variable frequency drives
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
Voltage rating - max |
240 V
|
Mounting position |
Vertical
|
Communication interface |
CANopen®, built in
OP-Bus (RS485), built in SmartWire-DT, optional Modbus RTU, built in |
Converter type |
U converter
|
Degree of protection |
NEMA 4X
IP66 |
Assigned motor power at 230/240 V, 60 Hz, 1-phase |
0.5 HP
|
Input current ILN at 150% overload |
6 A
|
Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload |
4.3 A
|
Assigned motor current IM at 230 V, 50 Hz, 150% overload |
4.3 A
|
Protocol |
EtherNet/IP
MODBUS CAN Other bus systems |
Overload current IL at 150% overload |
6.45 A
|
Rated frequency - max |
62 Hz
|
Rated frequency - min |
48 Hz
|
Rated operational power at 220/230 V, 50 Hz, 1-phase |
0.37 kW
|
System configuration type |
AC supply systems with earthed center point
|
Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
Braking torque |
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
|
Cable length |
75 m, unscreened, maximum permissible, Motor feeder
50 m, screened, maximum permissible, Motor feeder C3 ≤ 25 m, maximum motor cable length 150 m, unscreened, with motor choke, maximum permissible, Motor feeder C1 ≤ 1 m, maximum motor cable length C2 ≤ 5 m, maximum motor cable length 100 m, screened, with motor choke, maximum permissible, Motor feeder |
Output voltage (U2) |
230 V AC, single-phase
240 V AC, single-phase |
Number of inputs (analog) |
2
|
Number of inputs (digital) |
4
|
Radio interference class |
C1: for conducted emissions only
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. |
Number of outputs (digital) |
1
|
Starting current - max |
175 % IH
|
Number of phases (input) |
1
|
Number of relay outputs |
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
|
Number of phases (output) |
1
|
Power consumption |
45.75 W
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Efficiency |
97 % (η)
|
Supply frequency |
50/60 Hz
|
Leakage current at ground IPE - max |
2.49 mA
|
Mains voltage - min |
200 V
|
Nominal output current I2N |
4.3 A
|
Number of HW-interfaces (industrial ethernet) |
0
|
Number of HW-interfaces (other) |
0
|
Number of HW-interfaces (parallel) |
0
|
Number of HW-interfaces (RS-232) |
0
|
Number of HW-interfaces (RS-422) |
0
|
Number of HW-interfaces (RS-485) |
1
|
Number of HW-interfaces (serial TTY) |
0
|
Number of HW-interfaces (USB) |
0
|
Number of interfaces (PROFINET) |
0
|
Number of outputs (analog) |
1
|
Output at linear load at rated output voltage - max |
0.37 kW
|
Output at quadratic load at rated output voltage - max |
0.37 kW
|
Output frequency - max |
500 Hz
|
Output frequency - min |
0 Hz
|
Suitable for |
Branch circuits, (UL/CSA)
|
Switching frequency |
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
|
Rated operational current (Ie) |
4.3 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
|
Rated operational voltage |
230 V AC, 1-phase
240 V AC, 1-phase |
Short-circuit protection rating |
10 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|