Lae dokument alla () … 20

216551
Mudeli kood: M22-H4

Eaton Moeller® series M22 Shroud, for flush mounting plate, 4 mounting locations

General specifications

Product Name
Eaton Moeller® series M22 Accessory Shroud
Catalog Number
216551
EAN
4015082165512
Product Length/Depth
110 mm
Product Height
80 mm
Product Width
105 mm
Product Weight
0.181 kg
Compliances
Bureau Veritas
CE Marked
GoST-R
Certifications
CSA Certified
CCC Marked
Lloyd's Register Certified
CE
CSA Class No.: 3211-03
UL 508
CSA-C22.2 No. 14-05
IEC/EN 60947-5
CSA File No.: 012528
CSA-C22.2 No. 94-91
UL
CSA
UL File No.: E29184
UL Category Control No.: NKCR
Model Code
M22-H4

Omadused ja funktsioonid

Color
Gray
Knockouts
4 x M20 (cable entry knockouts at the base)
Material
Insulated material light
Number of locations
4
RAL-number
7035

Üldist

Degree of protection
NEMA 12
IP40
Protection
Protection type only in combination with flush mounting plates M22-E…
Size
22.5 mm
Type
Four-element

Ilmastikutingimused

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C

Kommunikatsioon

Connection to SmartWire-DT
No

Kontaktid

Force for positive opening - min
0 N

Vastavusavaldus

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Ekspordi toote tehnilised andmed