Photo is representative
Download
Eaton Moeller® series M22 LED element, for combination with RMQ-Titan operating elements M22-..., Base fixing, multicolor
| Product Name |
Eaton Moeller® series M22 LED element
|
| Catalog Number |
198598
|
| EAN |
4015081965724
|
| Product Length/Depth |
38 mm
|
| Product Height |
10 mm
|
| Product Width |
32 mm
|
| Product Weight |
0.015 kg
|
| Certifications |
IEC/EN 61131-2
UL Listed CSA Class No.: 3211-07 CSA File No.: 2324643 EN 50178 UL File No.: E29184 UL Category Control No.: NKCR CSA certified |
| Model Code |
M22-SWD-LEDC-RGB
|
| Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Fitted with: |
Light source
|
| Pollution degree |
2
|
| Burst impulse |
1 kV, Signal cable
2 kV, Supply cable |
| Connection to SmartWire-DT |
Yes
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-30 °C
|
| Ambient storage temperature - max |
80 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Force for positive opening - min |
0 N
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Rated operational voltage (Ue) at AC - max |
0 V
|
| Rated operational voltage (Ue) at AC - min |
0 V
|
| Rated operational voltage (Ue) at DC - max |
30 V
|
| Rated operational voltage (Ue) at DC - min |
30 V
|
| Color |
Multicolor
|
| Environmental conditions |
Condensation: prevent with appropriate measures
|
| Voltage type |
DC
|
| Fastening type |
Floor fastening
|
| Mounting position |
As required
|
| Light color |
Multi-colored
|
| Connection type |
Base fixing
SWD: Plug, 8-pole |
| Lamp type |
LED
|
| Connection |
SmartWire-DT plug connector M22-SWD-I…LP
|
| Overvoltage category |
Not applicable
|
| Connection type (auxiliary circuit) |
Flat plug-in connection
|
| Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
| Degree of protection |
IP20
|
| Functions |
For combination with RMQ-Titan operating elements M22-...
|
| Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
| Lamp holder |
None
|
| Electromagnetic fields |
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008) |
| Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Radio interference class |
Class A (EN 55011)
|
| Relative humidity |
9 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
| Lifespan, electrical |
100,000 h (at 25°C, according to EN60064)
|
| LED indicator |
Status indication of SmartWire-DT network: Green LED
|
| Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
| Station |
SmartWire-DT slave, SmartWire-DT network
|