Eaton Moeller® series M22 Buzzer BA9s.18-30V DC, continuous tone
Product Name |
Eaton Moeller® series M22 Accessory Acoustic indicator
|
Catalog Number |
229025
|
EAN |
4015082290252
|
Product Length/Depth |
30 mm
|
Product Height |
10 mm
|
Product Width |
10 mm
|
Product Weight |
0.014 kg
|
Compliances |
CE Marked
|
Certifications |
EN 60947-5
CSA Std. C22.2 No. 14-05 UL 508 IEC 60947-5 IEC/EN 60947-5 CSA Class No.: 3211-03 CSA File No.: 012528 UL File No.: E29184 CSA CE UL UL Category Control No.: NKCR CSA-C22.2 No. 14-05 |
Catalog Notes |
|
Model Code |
M22-XAM
|
Special features |
Continuous tone
|
Product Category |
Accessories
|
Voltage rating |
18-30 V
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Alarm type |
Continuous tone
Continuous tone, 18 - 30 V DC |
Connection to SmartWire-DT |
No
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Rated operational voltage (Ue) at AC - max |
0 V
|
Rated operational voltage (Ue) at AC - min |
0 V
|
Rated operational voltage (Ue) at DC - max |
30 V
|
Rated operational voltage (Ue) at DC - min |
18 V
|
Static heat dissipation, non-current-dependent Pvs |
0.4 W
|
Degree of protection |
NEMA Other
|
Voltage type |
DC
|
Loudness |
83 dB
|
Tone type |
Continuous tone
|