Reset
Eaton Moeller series NZMN2 PXR20 circuit breaker, 100 A, 3-pole, box terminal, UL/CSA
| Product Name |
Eaton Moeller series NZM molded case circuit breaker electronic
|
| Catalog Number |
192517
|
| Model Code |
NZMN2-VX100-BT-NA
|
| EAN |
4015081932450
|
| Product Length/Depth |
149 mm
|
| Product Height |
195 mm
|
| Product Width |
105 mm
|
| Product Weight |
2.345 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC 60947-2
CSA certified Specially designed for North America CSA (File No. 22086) CE marking UL (File No. E31593) CSA-C22.2 No. 5-09 UL (Category Control Number DIVQ) UL listed UL/CSA IEC CSA (Class No. 1432-01) UL 489 |
| Voltage rating |
690 V - 690 V
|
| Rated operating voltage Ue (UL) - max |
600 V
|
| Amperage Rating |
100 A
|
| Instantaneous current setting (Ii) - min |
2 A
|
| Instantaneous current setting (Ii) - max |
18 A
|
| Overload current setting (Ir) - min |
40 A
|
| Overload current setting (Ir) - max |
100 A
|
| Short delay current setting (Isd) - min |
200 A
|
| Short delay current setting (Isd) - max |
1000 A
|
| Short-circuit release delayed setting - min |
80 A
|
| Short-circuit release delayed setting - max |
1000 A
|
| Short-circuit release non-delayed setting - min |
200 A
|
| Short-circuit release non-delayed setting - max |
1800 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
50 kA
|
| Electrical connection type of main circuit |
Frame clamp
|
| Handle type |
Rocker lever
|
| Amperage Rating |
100 A
|
| Instantaneous current setting (Ii) - min |
2 A
|
| Instantaneous current setting (Ii) - max |
18 A
|
| Overload current setting (Ir) - min |
40 A
|
| Overload current setting (Ir) - max |
100 A
|
| Short delay current setting (Isd) - min |
200 A
|
| Short delay current setting (Isd) - max |
1000 A
|
| Short-circuit release delayed setting - min |
80 A
|
| Short-circuit release delayed setting - max |
1000 A
|
| Short-circuit release non-delayed setting - min |
200 A
|
| Short-circuit release non-delayed setting - max |
1800 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
50 kA
|
| Electrical connection type of main circuit |
Frame clamp
|
| Handle type |
Rocker lever
|
| Mounting Method |
Fixed
DIN rail (top hat rail) mounting optional Built-in device fixed built-in technique |
| Degree of protection |
IP20
|
| Protection against direct contact |
Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
|
| Number of auxiliary contacts (change-over contacts) |
0
|
| Number of auxiliary contacts (normally closed contacts) |
0
|
| Number of auxiliary contacts (normally open contacts) |
0
|
| Position of connection for main current circuit |
Front side
|