Eaton xEnergy Safety Ci LV systems LV switchgear. Base, individual enclosure, HxWxD=375x375x120mm
Product Name |
Eaton xEnergy Safety Ci empty enclosure base
|
Catalog Number |
069642
|
EAN |
4015080696421
|
Product Length/Depth |
150 mm
|
Product Height |
375 mm
|
Product Width |
375 mm
|
Product Weight |
3.757 kg
|
Compliances |
RoHS conform
|
Certifications |
EN 61439-2
EN 62208 |
Special features |
|
Type |
Basic enclosure
|
Features |
Cover with overpressure release
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
Meets the product standard's requirements.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
960 °C
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Not relevant to indoor installations.
|
10.2.5 Lifting |
20 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet.
|
10.2.6 Mechanical impact |
IK10
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
IP65, with cover
|
10.4 Clearances and creepage distances |
Is the panel builder's responsibility.
|
10.5 Protection against electric shock |
Protection class 2, therefore not applicable.
|
10.6 Incorporation of switching devices and components |
Is the panel builder's responsibility.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Ui = 1000 V AC
|
10.9.3 Impulse withstand voltage |
8 kV
|
10.9.4 Testing of enclosures made of insulating material |
Meets the product standard's requirements.
|
Accessory/spare part type |
Individual enclosure bottoms
|
Degree of protection |
IK10
IP65 Other |
Enclosure material |
Plastic
|
Surface protection |
Other
|
Circuit integrity |
Other
|
Base type |
Full-area knockouts
|
Unit type |
Modular system
|
Built-in depth |
250 mm
|
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890) |
23 W
|
Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890) |
21 W
|
Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890) |
22 W
|
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890) |
47 W
|
Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890) |
42 W
|
Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890) |
45 W
|
Color |
Gray
|
Cover/door model |
Closed
|
Cover/door type |
Optional
None |
Number of openings (flange plates) |
4
|
Plate thickness (cabinet) |
6 mm
|
Plate thickness (cover/door) |
6 mm
|
RAL-number |
7035
|
Width in number of modular spacings |
15
|
Cable entry type |
10 x M20
6 x M25/16 2 x M20 8 x M25/16 Transverse Top and bottom 2 x M16 1 x M63/40 2 x M40/25 1 x M50/32 |
Mounting method |
Surface mounted (plaster)
|
Number of rows |
0
|
Functions |
Extension possible
|
Protection class |
II
|
Number of modules |
1
|
Internal depth |
100 mm
|
Nominal current |
1600 A
|
Number of conduit inlets |
100
|
Suitable for |
Outdoor use
Lightning protection |
Enclosure material quality |
Other
|
Type of coating |
Other
|