Eaton DC1 Variable frequency drive, 115 V AC, single-phase, 5.8 A, 1.1 kW, IP66/NEMA 4X, Brake chopper, 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, FS2
Product Name |
Eaton DC1 Variable frequency drive
|
Catalog Number |
199398
|
EAN |
4015081977871
|
Product Length/Depth |
182 mm
|
Product Height |
257 mm
|
Product Width |
188 mm
|
Product Weight |
3.5 kg
|
Certifications |
UL Listed
UL File No.: E172143 Certified by UL for use in Canada UL report applies to both US and Canada UkrSEPRO CSA-C22.2 No. 14 IEC/EN61800-5 UL UL 508C EAC RoHS, ISO 9001 CUL IEC/EN 61800-2 IEC/EN 61800-3 RCM CE CE marking UL Category Control No.: NMMS, NMMS7 IEC/EN 61800-5-1 |
Features |
Parameterization: drivesConnect
Parameterization: Fieldbus Parameterization: Keypad Parameterization: drivesConnect mobile (App) |
Fitted with: |
Brake chopper
Local controls Internal DC link PC connection Additional PCB protection IGBT inverter 7-digital display assembly Breaking resistance UV resistance Control unit |
Functions |
4-quadrant operation possible
|
Cable length |
150 m, unscreened, maximum permissible cable length
100 m, screened, maximum permissible cable length 300 m, unscreened, with motor choke, maximum permissible, Motor feeder 200 m, screened, with motor choke, maximum permissible cable length |
Communication interface |
SmartWire-DT, optional
Modbus RTU, built in OP-Bus (RS485), built in CANopen®, built in |
Connection to SmartWire-DT |
No
|
Degree of protection |
NEMA 4X
IP66 |
Frame size |
FS2
|
Mounting position |
Vertical
|
Product category |
Variable frequency drives
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Protocol |
Other bus systems
MODBUS EtherNet/IP CAN |
Radio interference class |
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
|
Suitable for |
Branch circuits, (UL/CSA)
|
Altitude |
Above 1000 m with 1 % derating per 100 m
Max. 4000 m |
Ambient operating temperature - min |
-20 °C
|
Ambient operating temperature - max |
40 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
60 °C
|
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Efficiency |
97 % (η)
|
Input current ILN at 150% overload |
21.9 A
|
Leakage current at ground IPE - max |
4.8 mA
|
Mains switch-on frequency |
Maximum of one time every 30 seconds
|
Mains voltage - min |
110 V
|
Mains voltage - max |
115 V
|
Operating mode |
Sensorless vector control (SLV)
Synchronous reluctance motors Speed control with slip compensation PM motors U/f control BLDC motors |
Output frequency - min |
0 Hz
|
Output frequency - max |
500 Hz
|
Output voltage (U2) |
230 V AC, 3-phase
|
Overload current IL at 150% overload |
8.7 A
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Rated frequency - min |
48 Hz
|
Rated frequency - max |
62 Hz
|
Rated operational current (Ie) |
5.8 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
|
Rated operational power at 220/230 V, 50 Hz, 3-phase |
1.1 kW
|
Rated operational voltage |
115 V AC, 1-phase
|
Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
Short-circuit protection rating |
35 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
Starting current - max |
175 % IH
|
Supply frequency |
50/60 Hz
|
Switching frequency |
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
|
System configuration type |
AC supply systems with earthed center point
|
Voltage rating - max |
120 V
|
Assigned motor current IM at 230 V, 50 Hz, 150% overload |
4.6 A
|
Braking resistance |
100 Ω
|
Braking torque |
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit Max. 100 % of rated operational current Ie with external braking resistor - Main circuit |
Switch-on threshold for the braking transistor |
390 VDC
|
Number of inputs (analog) |
2
|
Number of inputs (digital) |
4
|
Number of outputs (analog) |
1
|
Number of outputs (digital) |
1
|
Number of relay outputs |
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
|