Photo is representative
Download
Eaton Touch panel XV-303, 24 V DC, 15.6 Inch, 2 x Ethernet, 1 x RS-232, 1 x RS-485, 1 x CAN, Linux, Capacitive multi touch
Product Name |
Eaton XV-303 Touch panel
|
Catalog Number |
EP-401369
|
EAN |
7640130100282
|
Product Length/Depth |
403.7 mm
|
Product Height |
67 mm
|
Product Width |
254.9 mm
|
Product Weight |
3.2 kg
|
Certifications |
CUL
CE Certified by UL for use in Canada IEC/EN 61000-6-2 IEC/EN 61000-6-4 UL UL 61010-2-201 UL File No.: E205091 |
Enclosure material |
Insulated material
|
Fitted with: |
1 x RS232 (built-in interface)
Color display 2 x Ethernet 10/100 Mbps (built-in interface) Printer output 1 x RS485 (built-in interface) Message indication SW interfaces 1 x USB host 2.0 (built-in interface) Message system (incl. buffer and confirmation) Recipes 1 x CAN (built-in interfaces) |
Functions |
Process value representation (output) possible
Additional software components, loadable Process default value (input) possible |
Battery runtime |
Back-up of real-time clock: BR 2330, non-replaceable (soldered)
|
Degree of protection |
NEMA 12
NEMA 4X IP20, rear (according to EN 60529-1) |
Degree of protection (front side) |
IP65
NEMA 12 |
Fuse type |
Built-in fuse (not accessible)
|
Lifespan |
50,000 h (Service life of back-lighting)
|
Model |
Plastic enclosure and glass panel in plastic frame
|
Mounting method |
Flush mounting - Clearance: Width x Height ≥ 50 mm (1.97"), Depth ≥ 20 mm (0.79")
Flush mounting - Inclination from vertical: ⍺ ≤ ± 10 ° (if using natural convection) Flush mounting - Mounting plate: min. 1.5 mm (0.06"), max. 4 mm Flush mounting - Inclination from vertical: ⍺ ≤ ± 45° at operating temperature ≤ 45°C (113°F) (if using natural convection) Flush mounting |
Potential isolation |
Power supply: no
|
Protection against polarity reversal |
Yes
|
Product category |
XV-300
|
RoHs conformity |
Yes
|
Software |
GALILEO, Visualization software, Engineering
|
Type |
Control panel with 2nd Ethernet port
|
Voltage type |
DC
|
Shock resistance |
15 g, 11 ms, Mechanical
|
Vibration resistance |
5 - 9 Hz, ± 3.5 mm
60 - 150 Hz, ± 2 g 9 - 60 Hz, ± 0.15 mm According to IEC/EN 60068-2-6 |
Air pressure |
795 - 1080 hPa (operation)
|
Ambient operating temperature - min |
0 °C
|
Ambient operating temperature - max |
50 °C
|
Ambient storage temperature - min |
-20 °C
|
Ambient storage temperature - max |
60 °C
|
Climatic proofing |
Cold to EN 60068-2-1
Damp heat, constant, to IEC 60068-2-3 Dry heat to IEC 60068-2-2 |
Environmental conditions |
Condensation: Non-condensing
|
Operating temperature - min |
0 °C
|
Operating temperature - max |
50 °C
|
Relative humidity |
10 - 95 % (non-condensing)
|
Emitted interference |
According to IEC/EN 61000-6-4
|
Interference immunity |
According to EN 61000-6-2
|
Voltage dips |
5 ms from undervoltage (19.2 V DC)
≤ 10 ms from rated voltage (24 V DC) |
Permissible voltage |
19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %)
35 V DC (for a duration of < 100 ms) 18.0 - 31.2 V DC, absolute with ripple 18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %) |
Power consumption |
Max. 21.6 W
16 W typ. 19.1 W |
Rated operational voltage |
24 V DC (power-supply - safety extra low voltage)
|
Supply voltage at AC, 50 Hz - min |
0 VAC
|
Supply voltage at AC, 50 Hz - max |
0 VAC
|
Supply voltage at DC - min |
19.2 VDC
|
Supply voltage at DC - max |
30 VDC
|
Interfaces |
10/100 Mbps Ethernet connection
CAN (not galvanically isolated, 9-pin SUB-D plug, UNC) RS485 (not galvanically isolated, 9-pin SUB-D plug, UNC) USB 2.0 host (not galvanically isolated) RS232 (not galvanically isolated, 9-pin SUB-D plug, UNC) |
Number of slots |
1 (for SD-Card)
|
Protocol |
EtherNet/IP
CAN TCP/IP MODBUS EtherCAT |
Display contrast ratio |
500:1
|
Display lighting |
LED
Dimmable via software |
Display size |
16:9
344.23 x 193.54 mm |
Display type |
TFT
Color display, TFT, anti-glare Anti-glare tempered glass in plastic bezel |
Luminance intensity |
400 cd/m²
|
Number of colors of the display |
16777216
|
Resolution |
|
Screen size (diagonal) |
15.6 in
|
Touch technology |
Multi-touch touch panel touch sensor
Capacitive multitouch Projected Capacitive Touch (PCT) |
Backup time |
10 years, typ. (time at zero voltage)
|
Memory |
DRAM: 512 MByte RAM
NVRAM: 128kByte Retain Flash: 1 GByte SLC SD card, Type: SDSC, SDHC (external memory) |
Memory capacity |
512,000 kByte
|
Operating system |
Linux
|
Processor |
ARM Cortex-A9 800 MHz
|
Equipment heat dissipation, current-dependent Pvid |
21.6 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
21.6 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|