The latest addition to Eaton's 9395 UPS family, the Eaton 9395XC UPS sets new market leading capabilities to manage growing data consumption demands today and in the future. Designed to anticipate the growing needs of data centers for large power capacity, the new solution has the smallest footprint with the highest power density on the market and delivers reliable, flexible power protection for everything from hyperscale and multi-tenant data centers to enterprise and light industrial applications. The 9395XC UPS, which is compatible with both VRLA batteries and cost-effective lithium-ion UPS batteries, is available in a 1500 kW model, the first in a series of monolithic UPS solutions, with additional models expected in the future. With Eaton’s Energy Saver System mode activated, the 9395XC UPS can reach 99 percent efficiency.
Easy deployment:
Compact:
Reliable:
UPS rating (unity power factor 1.0) | |
kW/kVA | 1500/1500 |
Efficiency | 99% in Energy Saver System (ESS) (up to 97.5% efficiency (480V) in double-conversion) |
Parallel capability | 4 UPS units maximum for distributed bypass and 2 UPS units maximum with SBM |
Audible noise | 73dBA @ 1 meter (50% load) 82dBA @ 1 meter (100% load) |
Altitude (max) | 1000m at 40 degree C (104 degree F) for 1500/1500 |
Input characteristics | |
Voltage | 480V 3W |
Voltage range | +10% / -15% |
Frequency range | 45–65 Hz |
Power factor | 0.99 for output loads greater than 60% |
Input current distortion | <3% (no input filter required) |
Soft start capability | Yes |
Output characteristics | |
Voltage | 480V 3W |
Regulation | ±1% |
Inverter | PWM |
Voltage THD | <1% (100% linear load); <5% (non-linear load) |
Load power factor range | Up to a 0.7 power factor leading/lagging without derating Up to a 0.5 power factor lagging with derating |
Overload | 110% for 10 min; 125% for 120 sec; 150% for 10 sec; >150% for 300 msec (UPS transfer to Bypass after OL time expires) |
Battery | |
Battery types | VRLA, AGM, wet cell, lithium-ion |
Battery voltage | 480V |
Charging method | ABM technology or float, selectable |
Dimensions (480V system) | |
1500 kW / 1500 kVA | 106”w x 33.7”d x 78.8”h |
General characteristics | |
Control panel | Color Touchscreen interface |
Battery startup | Standard |
Frequency conversion | Standard |
Multi-language | Standard |
Building alarm inputs | 5 (galvanic isolated) |
Individual fan fail monitoring | Included |
Power Semiconductor Temperature Monitoring | Included |
Options | External maintenance bypass PDU, RPP and STS Maintenance bypass module, 2/3/4 breaker DC disconnects Human Machine Interface (HMI) designs for monitoring of connected equipment |
PredictPulse remote monitoring and management service | PredictPulse is the industry’s first cloud-based 24x7 remote monitoring and predictive analytics subscription service to forecast data center power component failure and proactively replace components before failure. PredictPulse is included with the 9395XC UPS for the first year at no-charge along with the Eaton Environmental Monitoring Probe Gen 2 (customer self-installs via outbound email server or optional 4G/LTE wireless modem). |
Communications | Software compatibility: Software and Power Xpert Reporting The Eaton Gigabit Industrial Gateway Card can be installed at any time for the following protocols: HTTPS, TLS 1.2, SNMPv1, SNMPv3, NTP, TFTP, SMTP, SMTPS, BOOTP, DHCP, SLAAC, SSH, MQTTS, ModbusTCP, Modbus RTU, BACnet IP, BACnet BBMD Additional cards include: Eaton Environmental Monitoring Probe Gen 2 |