Download document () of 20
Automatic transfer switches

Transfer Switch Monitor 900

Eaton’s Transfer Switch Monitor 900 brings new life and modern intelligence to legacy transfer switches. Retrofit equipment with communication, power metering, and status monitoring to make informed decisions and facilitate system reporting.

TRANSFER SWITCH MODEL
Any manufacturer
SYSTEM VOLTAGE
Low voltage: Up to 600 Vac
Med voltage: Up to 46 KVac
SYSTEM CURRENT
Up to 5000A

Core features

  • Provides system level visibility of transfer switch status and condition
  • Measures and benchmarks real-time metering data (voltage, frequency, current, power)
  • Retrieves “transfer time” to comply with regulatory requirements including The Joint Commission Report
  • Facilitates centralized testing to reduce time and labor burden associated with canvassing facility, local test initiation, logging results and compiling records
  • Evaluates system loading and identifies reserve capacity
  • Provides insight into conditions leading up to an unplanned outage and guides corrective action

Automatic transfer switches

Reliable, rugged, versatile and compact assemblies for transferring essential loads and electrical distribution systems from one power source to another.


Watch the following videos to learn more:

  • What is WCR in automatic transfer switches?
  • Choosing a transfer switch
  • Recent change to National Electric code
  • UL1008 Short-circuit WCRs

    Automate your reporting and centralize your monitoring

    Foreseer and Power XpertTM reporting provide an enterprise power monitoring solution
    Specifications
    Complete product technical specifications and catalog number information, along with other related downloads, can be accessed in the resources section of this page.

    Ratings

    SYSTEM VOLTAGE

    Low voltage: Up to 600Vac

    Med Voltage: Up to 46KVac

    SYSTEM CURRENT Up to 5000A
    SYSTEM FREQUENCY 50 or 60 Hz

    Standards

    SAFETY UL 508A
    SEISMIC CERTIFICATION IBC, CBC, UBC Zone 4, OSHPD
    EMISSIONS FCC Part 15 (Subpart B); CISPR 11
    ELECTROMAGNETIC COMPATIBILITY (EMC)

    IEC 61000-4-2: electrostatic discharge immunity

    IEC 61000-4-3: radiated immunity

    IEC 61000-4-4: fast transient/burst immunity

    IEC 61000-4-5: surge immunity

    IEC 61000-4-6: conducted immunity

    IEC 61000-4-11: voltage dip/interruption immunity

    Devices

    COMMUNICATION CAENET Ethernet Adapter, Power Xpert Gateway 900, Power Xpert Ethernet switch
    METERING DCT module
    TIME SYNCHRONIZATION NTP client module
    PROGRAMMABLE INPUTS/OUTPUTS I/O expansion module

    Enclosure

    ENCLOSURE TYPE Indoor (NEMA 1) & outdoor (NEMA 3R)
    ENCLOSURE SIZES Standard and large
    STANDARD INDOOR DIMENSIONS 16.64x10.22x18.14 (WxDxH: inches)
    STANDARD OUTDOOR DIMENSIONS 16.64x10.84x19.74 (WxDxH: inches)
    LARGE INDOOR DIMENSIONS 16.64x10.22x28.89 (WxDxH: inches)
    LARGE OUTDOOR DIMENSIONS 16.64x10.84x30.49 (WxDxH: inches)
    ACCESS Front
    MOUNTING TYPES Internal & external (with flange)
    Download Links
    X
    Download Close

    Informational videos