Download document () of 20
Low Voltage Switchgear and Design Tools

xEnergy Elite

Eaton’s xEnergy Elite motor control centers and power distribution switchgear combine intelligent communications and industry-leading arc flash prevention to provide the safest, most effective method for grouping motor control, associated control, industrial communications and distribution equipment. xEnergy Elite is safe, durable and scalable, built to IEC 61439-2 standards and can be seamlessly integrated to all major industrial protocols.

Continuous Current
up to 7500 A
System Voltage
up to 690 V
Short Circuit Withstand
up to 120 kA

Keep your process running with our unique xEnergy Elite contact system

Thanks to the xEnergy Elite patented silver-plated contact system, you do not have to worry about stopping your process. You can easily swap or upgrade the removable units, without disrupting or isolating the entire system.

Patented unique contact system that enhances your performance and safety

Unlike other systems, our contacts ensure a reliable and efficient electrical connection that gets stronger as the currents increase during operation. Plus, our innovative design protects your operations from any short circuit damage by eliminating the stress on the contacts and busbar, ensuring the safety and continuity of your operations.

eaton-xenergy-decrease-maintenance

Ultimate safety during maintenance

  • With the xEnergy Elite drawers, you can perform three functions in one: disconnect, test and connect. No need to open the doors and risk your safety or compromise the protection level of up to IP54. The innovative contact system allows you to seamlessly switch between the functions with ease and confidence.
  • You can safely put the xEnergy Elite units back into the “live” panel without cabling them, for optimum safety of personnel.

Unique micro drawers

Thanks to Eaton’s xElite micro drawers, you can optimize your switchgear space. These innovative drawers come in half and quarter length sizes, giving you more flexibility and efficiency.

How does xEnergy Elite switchgear achieve passive arc fault protection?

xEnergy Elite meets the stringent IEC TR 61641 standard, criteria 1 to 7, arcing class C. It is meticulously designed to prevent the development of internal arc fault during normal operating conditions. It achieves this by incorporating arc ignition protected and arc tested areas within the switchgear.

Arc flash containment

The switchgear has smart features that limit any internal arc to the affected unit's compartment, protecting adjacent compartments and nearby personnel. The vertical busbar in the withdrawable units is fully insulated and separated. It is an 'arc ignition protected zone' as per IEC TR 61641, making it virtually maintenance-free. These features give xEnergy Elite switchgear a high level of passive arc fault protection, improving the performance and safety of the power distribution system.

Active arc flash protection

xEnergy Elite offers active arc flash protection devices for the highest safety and optimum process integrity.

  • Patented ARCON arc quenching device
  • Unique Arcflash Reduction Maintenance System™ (ARMS)
  • Continuous thermal monitoring thanks to Eaton’s DIAGNOSE system
Find out more: ARCON | ARMS | DIAGNOSE
xEnergy Elite Mannequin arcon

Earthquake protection

Earthquake protection is a top priority at Eaton. xEnergy Elite has a robust construction which has undergone seismic testing to the most stringent standards. xEnergy Elite is designed in such a way that without any additional measure it can be used in earthquake hazardous areas.
Specifications

Technical information

Eaton xEnergy Elite w-sections dimensional drawing
Eaton xEnergy Elite w-sections floor plan dimensional drawing
spacer

General

Rated operational voltage 400 V, 415 V, 525 V, 690 V
Rated frequency 50 Hz / 60 Hz
spacer

Main busbar data

Rated current up to 6300 A
Rated short-time withstand current up to 120 kA - 1s
Rated peak withstand current 264 kA
Rated insultation voltage
1000 VAC - 1200 VDC
spacer

Vertical distribution busbar data

Application withdrawable 1600 A
Rated short-time withstand current 80 kA / 1s
Rated peak withstand current 176 kA
Application removable 1800 A
Rated short-time withstand current 65 kA / 1s
Rated peak withstand current 143 kA
Rated insulation voltage
1000 V
spacer

Standards and regulations

xEnergy Elite complies with the most recent IEC regulations:

  • IEC 61439-1
  • IEC 61439-2 
  • IEC TR 61641 criteria 1 to 7
  • IEC 60068-3-3
  • Seismic level AG2 - AG5
spacer

xEnergy Elite production facilities comply with the following standards:

  • ISO 9001 for quality management
  • ISO 14001 for environmental management
  • ISO 50001 for energy management
spacer
Download Links
X