Eaton Moeller® series PKZ0 Current limiter, 3p, 63A, 400VAC/100kA, 690VAC/10kA
Product Name |
Eaton Moeller® series PKZ0 Current limiter
|
Catalog Number |
082881
|
EAN |
4015080828815
|
Model Code |
CL-PKZ0
|
Product Length/Depth |
56 mm
|
Product Height |
90 mm
|
Product Width |
45 mm
|
Product Weight |
0.201 kg
|
Certifications |
CSA Class No.: 3211-05
UL 508 CSA-C22.2 No. 14 IEC/EN 60947-4-1 CE UL Category Control No.: NLRV CSA CSA File No.: 165628 UL UL File No.: E36332 |
Functions |
Short-circuit current limiter
Can be used for individual and group protection |
Mounting Method |
DIN rail
|
Mounting position |
Next to or behind the motor protective circuit breaker
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Accessories
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Type |
Motor-protective circuit-breaker, non-auto-protected in order to increase switching capacity
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Rated uninterrupted current (Iu) |
63 A
|
Rated conditional short-circuit current (Iq) |
0 kA
|
Equipment heat dissipation, current-dependent Pvid |
8.4 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
2.8 W
|
Rated operational current for specified heat dissipation (In) |
63 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|