Eaton PV Main switch, T0, 20 A, surface mounting, 1 contact unit(s), 2 pole, STOP function, Lockable in the 0 (Off) position PV-20A-2P-AC-I1/SVB-SW
Product Name |
Eaton PV maintenance switch
|
Catalog Number |
199535
|
EAN |
5027590552158
|
Model Code |
PV-20A-2P-AC-I1/SVB-SW
|
Product Length/Depth |
137 mm
|
Product Height |
110 mm
|
Product Width |
80 mm
|
Product Weight |
274 g
|
Compliances |
CE
|
Features |
Version as main switch
Version as maintenance-/service switch |
Actuator color |
Black
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
UV resistance only in connection with protective shield.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Rated permanent current at AC-21, 400 V |
20 A
|
Rated permanent current at AC-23, 400 V |
13.3 A
|
Rated uninterrupted current (Iu) |
20 A
|
Switching power at 400 V |
5.5 kW
|
Device construction |
Complete device in housing
|
Rated short-time withstand current (Icw) |
0.32 kA
|
Electrical connection type of main circuit |
Screw connection
|
Actuator type |
Door coupling rotary drive
|
Number of auxiliary contacts (change-over contacts) |
0
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Rated conditional short-circuit current (Iq) |
6 kA
|
Degree of protection (front side) |
IP20
|
Number of poles |
Two-pole
|
Degree of protection |
NEMA Other
|
Suitable for |
Ground mounting
|
Functions |
Interlockable
|
Number of switches |
1
|
Number of auxiliary contacts (normally open contacts) |
0
|
Rated operating voltage (Ue) - max |
690 V
|
Rated operating voltage (Ue) - min |
690 V
|
Rated operational power at AC-23A, 400 V, 50 Hz |
5.5 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
5.5 kW
|
Housing material |
Plastic
|