Eaton Moeller® series LSE Safety position switch, LSE, Position switch with electronically adjustable operating point, Basic device, expandable, 1 N/O, 1 NC, Yellow, Insulated material, Cage Clamp, -25 - +70 °C
Product Name |
Eaton Moeller® series LSE Safety position switch
|
Catalog Number |
266121
|
EAN |
4015082661212
|
Model Code |
LSE-11
|
Product Length/Depth |
33.5 mm
|
Product Height |
76.5 mm
|
Product Width |
31 mm
|
Product Weight |
0.048 kg
|
Certifications |
CE
CSA File No.: 012528 CSA-C22.2 No. 14 UL UL Category Control No.: NKCR CSA Class No.: 3211-03 UL 508 CSA IEC/EN 61000-4 UL File No.: E29184 IEC/EN 60947-5 IEC/EN 60947 |
Electric connection type |
Cable entry metrical
|
Enclosure color |
Yellow Cover
|
Enclosure material |
Plastic
Insulated material |
Features |
Expandable
|
Fitted with: |
Status indication
|
Functions |
Output electronic
|
Indication |
Visual status indication
|
Switch function type |
Slow-action switch
|
Connection type |
Cage Clamp
|
Degree of protection |
IP66/IP67
NEMA Other |
Operating frequency |
3000 Operations/h
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
Position switch
|
Rated switching distance (Sn) - min |
0.5 mm
|
Rated switching distance (Sn) - max |
5.5 mm
|
Repetition accuracy |
0.02 mm (Contacts/switching capacity)
|
Suitable for |
Safety functions
|
Switching hysteresis of Sn |
0.4 %
|
Type |
Safety position switch
|
Mounting position |
As required
|
Shock resistance |
30 g, Basic unit, Mechanical, Half-Sinusoidal shock 20 ms
|
Temperature resistance |
100 °C, Contact temperature of roller head
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
70 °C
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Air discharge |
8 kV, according to IEC/EN 61000-4-2, Level 3, ESD
|
Burst impulse |
2 kV, Supply cable, according to IEC/EN 61000-4-4, Level 3
2 kV, Signal cable, according to IEC/EN 61000-4-4, Level 3 |
Contact discharge |
4 kV, according to IEC/EN 61000-4-2, Level 3, ESD
|
Electromagnetic fields |
10 V/m (according to IEC EN 61000-4-3)
|
Immunity to line-conducted interference |
10 V (according to IEC/EN 61000-4-6)
|
Surge rating |
0.5 kV, Power pulses (Surge), according to IEC/EN 61000-4-5, EMC
|
Terminal capacity (flexible with ferrule) |
1 x (0.5 - 1.5) mm²
|
Terminal capacity (solid) |
1 x (0.5 - 2.5) mm²
|
Rated breaking capacity |
0.019 A (30 V DC)
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
0 A
|
Rated operational current (Ie) at AC-15, 24 V |
0 A
|
Rated operational current (Ie) at DC-1, 12 V |
0.015 A
|
Rated operational current (Ie) at DC-1, 24 V |
18 A
|
Rated operational current (Ie) at DC-13, 125 V |
0 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0 A
|
Rated operational current (Ie) at DC-13, 24 V |
0.2 A
|
Rated operational voltage |
12 - 30 V DC
|
Actuating force at beginning/end of stroke |
3.5 N/8.0 N
|
Actuating torque of rotary drives |
0.2 Nm
|
Actuator type |
Plunger
|
Operating speed |
For angle of actuation α = 0°/30°
Max. 1/0.5 m/s (with DIN cam, mechanical actuation) |
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Explosion safety category for gas |
None
|
Explosion safety category for dust |
None
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.15 W
|
Rated operational current for specified heat dissipation (In) |
0.2 A
|
Static heat dissipation, non-current-dependent Pvs |
0.4 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|