Eaton Moeller series NZM - Molded Case Circuit Breaker. Socket base, 3p, 630A
Product Name |
Eaton Moeller series NZM plug-in unit
|
Catalog Number |
266711
|
EAN |
4015082667115
|
Model Code |
NZM3-XAVS
|
Product Length/Depth |
226 mm
|
Product Height |
342 mm
|
Product Width |
227 mm
|
Product Weight |
12.043 kg
|
Compliances |
IEC
RoHS conform |
Certifications |
IEC/EN 60947
|
Features |
Version as built-in device
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Frame |
NZM3
|
Mounting Method |
Withdrawable
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Equipment heat dissipation, current-dependent |
83.35 W
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
40 °C
|
Nominal current |
610 A
|
Protection against direct contact |
Finger and back-of-hand proof to VDE 0106 part 100
|
Terminal equipment included |
Screw connection
|
Isolation |
300 V AC (between the auxiliary contacts)
500 V AC (between auxiliary contacts and main contacts) |
Degree of protection |
IP2X (in the area of the plug-in area)
|
Direction of incoming supply |
As required
|
Electrical connection type of main circuit |
Screw connection
|
Mounting position |
Vertical and 90° right/left
|
Number of poles |
Three-pole
|
Type |
|
Shock resistance |
20 g (half-sinusoidal shock 20 ms)
|