Eaton DG1 Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, Brake chopper, DC link choke
Product Name |
Eaton DG1 variable frequency drive
|
Catalog Number |
9703-5010-00P
|
EAN |
4015081772247
|
Model Code |
DG1-35125FB-C21C
|
Product Length/Depth |
340.7 mm
|
Product Height |
888.5 mm
|
Product Width |
288 mm
|
Product Weight |
76.2 kg
|
Certifications |
UL508
Safety requirements: IEC/EN 61800-5 UkrSEPRO IEC/EN 61800-3 RoHS, ISO 9001 EAC UL report applies to both US and Canada IEC/EN61800-3 CUL Specification for general requirements: IEC/EN 61800-2 UL File No.: E134360 UL CE Certified by UL for use in Canada IEC/EN61800-5 CSA-C22.2 No. 274-13 C-Tick UL Category Control No.: NMMS, NMMS7 |
Catalog Notes |
The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
|
Product Category |
Variable frequency drives
|
Features |
Externally accessible fan
Parameterization: Fieldbus Parameterization: Keypad Parameterization: Power Xpert inControl |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Internal DC link
Additional PCB protection Multi-line graphic display DC link choke Radio interference suppression filter Brake chopper IGBT inverter Control unit PC connection Breaking resistance |
Pollution degree |
2
|
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Connection to SmartWire-DT |
In conjunction with DXG-NET-SWD SmartWire DT module
Yes |
Operating mode |
U/f control
Sensorless vector control (SLV) Torque regulation Speed control with slip compensation |
Frame size |
FS5
|
Air volume capacity |
395 m³/h
|
Altitude |
Max. 2000 m
Max. 1000 m Above 1000 m with 1 % derating per 100 m |
Environmental class |
3C2, 3S2 (Air quality)
|
Application in domestic and commercial area permitted |
Yes
|
Mains switch-on frequency |
Maximum of one time every 60 seconds
|
Application in industrial area permitted |
Yes
|
Ambient operating temperature - max |
50 °C
|
Ambient operating temperature - min |
-10 °C
|
Ambient operating temperature at 150% overload - max |
50 °C
|
Ambient operating temperature at 150% overload - min |
-30 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Apparent power at 600 V |
149.6 kVA
|
Mounting position |
Vertical
|
Rated conditional short-circuit current (Iq) |
100 kA
|
Relative symmetric net frequency tolerance |
10 %
|
Relative symmetric net voltage tolerance |
10 %
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Heat dissipation details |
Operation (with 150 % overload), allow for derating
|
Rated operational power at 525 V, 50 Hz, 3-phase |
75 kW
|
Rated operational power at 525 V, 50 Hz, 3-phase, 110% overload |
90 kW
|
Rated operational power at 600 V, 50 Hz, 3-phase |
90 kW
|
Rated operational power at 600 V, 50 Hz, 3-phase, 110% overload |
110 kW
|
Resolution |
0.01 Hz (Frequency resolution, setpoint value)
|
Static heat dissipation, non-current-dependent Pvs |
27.23 W
|
Switch-on threshold for the braking transistor |
1050 VDC
|
Voltage rating - max |
600 VAC
|
Overvoltage category |
III
|
Communication interface |
BACnet MS/TP, built in
PROFIBUS, optional SmartWire-DT, optional Modbus RTU, built in Modbus TCP, built in Ethernet IP, built in CANopen®, optional DeviceNet, optional |
Converter type |
U converter
|
Degree of protection |
NEMA 1
IP21 |
Protocol |
PROFIBUS
TCP/IP CAN MODBUS DeviceNet PROFINET IO Other bus systems BACnet EtherNet/IP |
Assigned motor current IM at 525 V, 50 Hz, 110% overload |
129 A
|
Assigned motor current IM at 525 V, 50 Hz, 150% overload |
107 A
|
Assigned motor current IM at 550 - 600 V, 60 Hz, 150% overload |
99 A
|
Assigned motor current IM at 600 V, 50 Hz, 110% overload |
137 A
|
Assigned motor current IM at 600 V, 50 Hz, 150% overload |
112 A
|
Assigned motor current IM at 600 V, 60 Hz, 110% overload |
125 A
|
System configuration type |
TN-S, TN-C, TN-C-S, TT, IT
|
Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
Assigned motor power at 575/600 V, 60 Hz, 3-phase |
125 HP
|
Assigned motor power at 575/600 V, 60 Hz, 3-phase, 110 % overload |
150 HP
|
Braking resistance |
7 Ω
|
Equipment heat dissipation, current-dependent Pvid |
1627 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Input current ILN at 110% overload |
132.9 A
|
Input current ILN at 150% overload |
116.2 A
|
Mains current distortion |
28.4 %
|
Current limitation |
0.1 - 2 x IH (CT), motor, main circuit
|
Number of slots |
2 (expansion)
|
Braking torque |
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit Adjustable to 150 % (I/Ie), DC - Main circuit Adjustable to 150 %, DC - Main circuit |
Cable length |
C3 ≤ 10 m, Radio interference level, maximum motor cable length
200 m, screened, maximum permissible, Motor feeder |
Functions |
4-quadrant operation possible
|
Output voltage (U2) |
600 V AC, 3-phase
|
Number of inputs (analog) |
2
|
Number of inputs (digital) |
8
|
Radio interference class |
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments C1: with external filter, for conducted emissions only |
Number of outputs (digital) |
1
|
Starting current - max |
200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section
|
Number of phases (input) |
3
|
Number of relay outputs |
3 (parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 V AC) / 6 A (24 V DC))
|
Number of phases (output) |
3
|
Power consumption |
1627 W
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Efficiency |
98.6 % (η)
|
Rated control voltage (Uc) |
24 V DC (external, max. 250 mA options incl.)
|
Supply frequency |
50/60 Hz
|
Leakage current at ground IPE - max |
11.2 mA
|
Mains voltage - max |
600 V
|
Mains voltage - min |
525 V
|
Nominal output current I2N |
125 A
|
Number of HW-interfaces (industrial ethernet) |
1
|
Number of HW-interfaces (other) |
1
|
Number of HW-interfaces (parallel) |
0
|
Number of HW-interfaces (RS-232) |
0
|
Number of HW-interfaces (RS-422) |
0
|
Number of HW-interfaces (RS-485) |
1
|
Number of HW-interfaces (serial TTY) |
0
|
Number of HW-interfaces (USB) |
0
|
Number of interfaces (PROFINET) |
0
|
Number of outputs (analog) |
2
|
Output at linear load at rated output voltage - max |
90 kW
|
Output at quadratic load at rated output voltage - max |
110 kW
|
Output frequency - max |
400 Hz
|
Output frequency - min |
0 Hz
|
Output voltage - max |
600 V
|
Overload current IL at 110% overload |
158.4 A
|
Overload current IL at 150% overload |
187.5 A
|
Shock resistance |
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) UPS drop test (for weights inside the UPS frame) |
Suitable for |
Branch circuits, (UL/CSA)
|
Switching frequency |
1.5 kHz, 1 - 6 kHz adjustable, fPWM, Power section, Main circuit
|
Rated operational voltage |
600 V AC, 3-phase
|
Short-circuit protection rating |
200 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
Vibration |
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak) Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude |
Rated frequency - max |
66 Hz
|
Rated frequency - min |
45 Hz
|
Rated operational current (Ie) at 110% overload |
144 A
|
Rated operational current (Ie) at 150% overload |
125 A
|
Rated operational current for specified heat dissipation (In) |
125 A
|
Safety function/level |
STO (Safe Torque Off, SIL1, PLc Cat 1)
|
Heat dissipation at current/speed |
1190 W at 100% current and 0% speed
1425 W at 50% current and 0% speed 1606 W at 100% current and 90% speed 430 W at 25% current and 0% speed 517 W at 25% current and 50% speed 663 W at 100% current and 50% speed 794 W at 50% current and 50% speed 868 W at 50% current and 90% speed |