Eaton Moeller series NZM - Molded Case Circuit Breaker. Connection width extension, 3p, 2 studs, size 3
| Product Name |
Eaton Moeller series NZM connection type
|
| Catalog Number |
119861
|
| Model Code |
NZM4-XKV95-2KB
|
| EAN |
4015081177127
|
| Product Length/Depth |
128 mm
|
| Product Height |
130 mm
|
| Product Width |
120 mm
|
| Product Weight |
3.3 kg
|
| Compliances |
UL/CSA
IEC RoHS conform |
| Certifications |
UL listed
UL (File No. E31593) UL489 IEC60947 CE marking CSA (Class No. 1432-01) UL (Category Control Number DIHS) CSA-C22.2 No. 5-09 CSA certified CSA (File No. 22086) |
| Model Code |
NZM4-XKV95-2KB
|
| Used with |
NZM4, N(S)4
|
| Amperage Rating |
1600 A
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Frame |
NZM4
|
| Suitable for |
Copper cable lugs
Three-pole |
| Number of poles |
Three-pole
|
| Terminal capacity (copper strip) |
10 segments of 80 mm x 1 mm (2x)
|
| Model |
Other
|
| Type |
Accessory
Connection width extension
Terminal
|
| Special features |
Two M12 threaded studs
|
| Terminal capacity (stranded cable) |
95 mm² - 300 mm² (4x)
500 AWG/kcmil (4x) |
| Terminal capacity (copper busbar) |
10 mm x 80 mm (2x)
|