Eaton S811 Soft starter, 361 A, 200 - 690 V AC, Us= 24 V DC, with control unit and pump algorithm, for 690-V grids, Frame size V
| Product Name | 
                                            
                                            
                                             
                                                Eaton S811 Soft starter
                                             
                                         | 
                                    
| Catalog Number | 
                                            
                                            
                                             
                                                168995
                                             
                                         | 
                                    
| Model Code | 
                                            
                                            
                                             
                                                S811+V36V3S
                                             
                                         | 
                                    
| EAN | 
                                            
                                            
                                             
                                                4015081654901
                                             
                                         | 
                                    
| Product Length/Depth | 
                                            
                                            
                                             
                                                187.8 mm
                                             
                                         | 
                                    
| Product Height | 
                                            
                                            
                                             
                                                420.8 mm
                                             
                                         | 
                                    
| Product Width | 
                                            
                                            
                                             
                                                280.6 mm
                                             
                                         | 
                                    
| Product Weight | 
                                            
                                            
                                             
                                                41.4 kg
                                             
                                         | 
                                    
| Certifications | 
                                            
                                            
                                             
                                                C-Tick  
                                        UL Category Control No.: NMFT GB14048 CE UL File No.: E202571 UL 508 CSA22.2-14-1995 UL CCC CSA IEC/EN 60947-4-2  | 
                                    
| Model Code | 
                                            
                                            
                                             
                                                S811+V36V3S
                                             
                                         | 
                                    
| Type | 
                                            
                                            
                                             
                                                Soft starter for three-phase loads, with control unit and pump algorithm, for 690-V grids
                                             
                                         | 
                                    
| 10.10 Temperature rise | 
                                            
                                            
                                             
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             
                                         | 
                                    
| 10.11 Short-circuit rating | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.12 Electromagnetic compatibility | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.13 Mechanical function | 
                                            
                                            
                                             
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             
                                         | 
                                    
| 10.2.2 Corrosion resistance | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.5 Lifting | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.6 Mechanical impact | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.7 Inscriptions | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.3 Degree of protection of assemblies | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.4 Clearances and creepage distances | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.5 Protection against electric shock | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.6 Incorporation of switching devices and components | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.7 Internal electrical circuits and connections | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.8 Connections for external conductors | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.2 Power-frequency electric strength | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.3 Impulse withstand voltage | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.4 Testing of enclosures made of insulating material | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| Fitted with: | 
                                            
                                            
                                             
                                                Display  
                                        Internal bypass contacts Internal bypass Motor overload protection  | 
                                    
| Pollution degree | 
                                            
                                            
                                             
                                                3
                                             
                                         | 
                                    
| Class | 
                                            
                                            
                                             
                                                Adjustable
                                             
                                         | 
                                    
| Climatic proofing | 
                                            
                                            
                                             
                                                Damp heat, constant, to IEC 60068-2-3  
                                        Damp heat, cyclic, to IEC 60068-2-30  | 
                                    
| Connection to SmartWire-DT | 
                                            
                                            
                                             
                                                No
                                             
                                         | 
                                    
| Rated impulse withstand voltage (Uimp) | 
                                            
                                            
                                             
                                                4000 V
                                             
                                         | 
                                    
| Frame size | 
                                            
                                            
                                             
                                                V
                                             
                                         | 
                                    
| Altitude | 
                                            
                                            
                                             
                                                Max. 2000 m  
                                        Above 2000 m with 0.5 % derating per 100 m  | 
                                    
| Number of inputs | 
                                            
                                            
                                             
                                                1 (current input)
                                             
                                         | 
                                    
| Ambient operating temperature - max | 
                                            
                                            
                                             
                                                50 °C
                                             
                                         | 
                                    
| Ambient operating temperature - min | 
                                            
                                            
                                             
                                                -30 °C
                                             
                                         | 
                                    
| Ambient storage temperature - max | 
                                            
                                            
                                             
                                                70 °C
                                             
                                         | 
                                    
| Ambient storage temperature - min | 
                                            
                                            
                                             
                                                -50 °C
                                             
                                         | 
                                    
| Assigned motor power at 200/208 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                125 HP
                                             
                                         | 
                                    
| Assigned motor power at 220/230 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                150 HP
                                             
                                         | 
                                    
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                300 HP
                                             
                                         | 
                                    
| Assigned motor power at 600 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                350 HP
                                             
                                         | 
                                    
| Assigned motor power at 690 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                450 HP
                                             
                                         | 
                                    
| Assigned motor power in-delta at 690 V, 60 Hz | 
                                            
                                            
                                             
                                                750 HP
                                             
                                         | 
                                    
| Equipment heat dissipation, current-dependent Pvid | 
                                            
                                            
                                             
                                                25 W
                                             
                                         | 
                                    
| Heat dissipation capacity Pdiss | 
                                            
                                            
                                             
                                                0 W
                                             
                                         | 
                                    
| Heat dissipation per pole, current-dependent Pvid | 
                                            
                                            
                                             
                                                0 W
                                             
                                         | 
                                    
| Mains voltage - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Mains voltage - min | 
                                            
                                            
                                             
                                                200 V
                                             
                                         | 
                                    
| Output voltage | 
                                            
                                            
                                             
                                                120 V AC/DC (relay outputs)
                                             
                                         | 
                                    
| Number of outputs | 
                                            
                                            
                                             
                                                2 Relay Outputs (programmable)
                                             
                                         | 
                                    
| Screwdriver size | 
                                            
                                            
                                             
                                                0.6 x 3.5 mm, Terminal screws, Control circuit cables
                                             
                                         | 
                                    
| Voltage type | 
                                            
                                            
                                             
                                                DC
                                             
                                         | 
                                    
| Rated operational voltage (Ue) - min | 
                                            
                                            
                                             
                                                200 V
                                             
                                         | 
                                    
| Rated power three-phase motor, inline, at 230 V | 
                                            
                                            
                                             
                                                110 kW
                                             
                                         | 
                                    
| Rated power three-phase motor, inline, at 400 V | 
                                            
                                            
                                             
                                                200 kW
                                             
                                         | 
                                    
| Rated power three-phase motor, inside delta, at 230 V | 
                                            
                                            
                                             
                                                200 kW
                                             
                                         | 
                                    
| Rated power three-phase motor, inside delta, at 400 V | 
                                            
                                            
                                             
                                                315 kW
                                             
                                         | 
                                    
| Static heat dissipation, non-current-dependent Pvs | 
                                            
                                            
                                             
                                                25 W
                                             
                                         | 
                                    
| Voltage rating - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Application | 
                                            
                                            
                                            
  | 
                                    
| Protection | 
                                            
                                            
                                             
                                                Finger and back-of-hand proof, Protection against direct contact
                                             
                                         | 
                                    
| Mounting position | 
                                            
                                            
                                             
                                                As required
                                             
                                         | 
                                    
| Input current | 
                                            
                                            
                                             
                                                4 - 20 mA (Analog inputs)
                                             
                                         | 
                                    
| Drop-out voltage | 
                                            
                                            
                                             
                                                0 - 3 V, DC operated
                                             
                                         | 
                                    
| Overvoltage category | 
                                            
                                            
                                             
                                                II
                                             
                                         | 
                                    
| Degree of protection | 
                                            
                                            
                                             
                                                IP00  
                                        NEMA Other  | 
                                    
| Current consumption | 
                                            
                                            
                                             
                                                100 mA, Control circuit, Digital inputs, External 24 V (no-load)  
                                        1400 mA, Control circuit, Regulator supply 10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC 150 mA, Control circuit, Digital inputs, External 24 V  | 
                                    
| Functions | 
                                            
                                            
                                             
                                                Suppression of closing transients  
                                        Underload monitoring Min. ramp time 1 s - fast switching (semiconductor contactor) Soft start function Current limitation Potential isolation between power and control sections Overload monitoring Suppression of DC components for motors Single direction  | 
                                    
| Delay time | 
                                            
                                            
                                             
                                                0 - 120 s, Soft start function, Ramp times
                                             
                                         | 
                                    
| Overload cycle | 
                                            
                                            
                                             
                                                AC-53a: 4.0 - 32: 99 - 3
                                             
                                         | 
                                    
| Drop-out time | 
                                            
                                            
                                             
                                                100 ms, DC operated
                                             
                                         | 
                                    
| Pick-up voltage | 
                                            
                                            
                                             
                                                21.6 - 26.4 V DC
                                             
                                         | 
                                    
| Radio interference class | 
                                            
                                            
                                             
                                                Class A (EN 55011)
                                             
                                         | 
                                    
| Fault memory | 
                                            
                                            
                                             
                                                10 Faults
                                             
                                         | 
                                    
| Pick-up time | 
                                            
                                            
                                             
                                                100 ms at DC
                                             
                                         | 
                                    
| Interfaces | 
                                            
                                            
                                             
                                                Modbus RTU (built-in)
                                             
                                         | 
                                    
| Kickstart | 
                                            
                                            
                                             
                                                Max. 2000 ms (Kickstart Duration)  
                                        100% (Kickstart voltage)  | 
                                    
| Rated control voltage (Uc) | 
                                            
                                            
                                             
                                                24 V DC  
                                        24 V DC (-10 %/+10 %)  | 
                                    
| Supply frequency | 
                                            
                                            
                                             
                                                50/60 Hz, fLN, Main circuit
                                             
                                         | 
                                    
| Terminal capacity (stranded) | 
                                            
                                            
                                             
                                                2 x (120 - 240) mm², Main cables  
                                        2 x (1 - 2.5) mm², Control circuit cables 6 x (120 - 240) mm², Main cables 1 x (2.5 - 4) mm², Control circuit cables 4 x (70 - 240) mm², Main cables  | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - max | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-11 | 
                                            
                                            
                                             
                                                3 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-53 | 
                                            
                                            
                                             
                                                360 A
                                             
                                         | 
                                    
| Rated operational current for specified heat dissipation (In) | 
                                            
                                            
                                             
                                                361 A
                                             
                                         | 
                                    
| Rated operational power at 220/230 V, 50 Hz | 
                                            
                                            
                                             
                                                110 kW
                                             
                                         | 
                                    
| Rated operational power at 400 V, 50 Hz | 
                                            
                                            
                                             
                                                200 kW
                                             
                                         | 
                                    
| Rated operational power at 500 V, 50 Hz | 
                                            
                                            
                                             
                                                250 kW
                                             
                                         | 
                                    
| Rated operational power at 690 V, 50 Hz | 
                                            
                                            
                                             
                                                315 kW
                                             
                                         | 
                                    
| Rated operational voltage (Ue) - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Ramp/run-up time | 
                                            
                                            
                                             
                                                360 s
                                             
                                         | 
                                    
| Shock resistance | 
                                            
                                            
                                             
                                                15 g, Mechanical
                                             
                                         | 
                                    
| Suitable for | 
                                            
                                            
                                             
                                                Branch circuits, not as BCPD, (UL/CSA)
                                             
                                         | 
                                    
| Tightening torque | 
                                            
                                            
                                             
                                                0.4 Nm, Screw terminals, Control circuit cables
                                             
                                         | 
                                    
| Short-circuit protection rating | 
                                            
                                            
                                             
                                                NZMN3-S400, Type “1” coordination, Main conducting paths
                                             
                                         | 
                                    
| Start voltage | 
                                            
                                            
                                             
                                                Max. 85 %, Soft start function, Start voltage = turn-off voltage
                                             
                                         | 
                                    
| Startup class | 
                                            
                                            
                                             
                                                CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)  
                                        CLASS 30 (6 x Iₑ for 30 s) CLASS 10 (star-delta replacement)  | 
                                    
| Terminal capacity (flexible with ferrule) | 
                                            
                                            
                                             
                                                2 x (1 - 2.5) mm², Control circuit cables  
                                        2 x (120 - 240) mm², Main cables 6 x (120 - 240) mm², Main cables 4 x (70 - 240) mm², Main cables 1 x (2.5 - 4) mm², Control circuit cables  | 
                                    
| Terminal capacity (solid) | 
                                            
                                            
                                             
                                                4 x (70 - 240) mm², Main cables  
                                        1 x (2.5 - 4) mm², Control circuit cables 2 x (120 - 240) mm², Main cables 2 x (1 - 2.5) mm², Control circuit cables 6 x (120 - 240) mm², Main cables  | 
                                    
| Terminal capacity (solid/stranded AWG) | 
                                            
                                            
                                             
                                                4 x (4 - 500 kcmil), Main cables  
                                        1 x (14 - 12), Control circuit cables 2 x (4 - 500 kcmil), Main cables 6 x (4 - 500 kcmil), Main cables 2 x (14 - 12), Control circuit cables  |