Eaton Moeller® series SDAINL Star-delta contactor combination, 380 V 400 V: 22 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation
Product Name |
Eaton Moeller series star-delta contactor combination
|
Catalog Number |
278386
|
Model Code |
SDAINLM45(230V50HZ,240V60HZ)
|
EAN |
4015082783860
|
Product Length/Depth |
138 mm
|
Product Height |
95 mm
|
Product Width |
158 mm
|
Product Weight |
1.61 kg
|
Certifications |
CE
|
Model Code |
SDAINLM45(230V50HZ,240V60HZ)
|
Used with |
ETR4-51
|
Electrical connection type for auxiliary- and control-current circuit |
Screw connection
|
Number of poles |
Three-pole
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Frequency rating |
50-60 Hz
|
Pollution degree |
3
|
Utilization category |
AC-3: Normal AC induction motors: starting, switch off during running
|
Connection |
Screw terminals
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Ambient operating temperature (enclosed) - min |
-25 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
-40 °C
|
Equipment heat dissipation, current-dependent Pvid |
12.4 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
4.1 W
|
Application |
Star-delta motor starting for contactor combinations
|
Product category |
Contactor combinations
|
Electrical connection type of main circuit |
Screw connection
|
Voltage type |
AC
|
Degree of protection |
IP00
NEMA Other |
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
3
|
Number of contacts (normally closed) as main contact |
0
|
Number of main contacts (normally open contact) |
9
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
230 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
230 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
240 V
|
Overvoltage category |
III
|
Duty factor |
100 %
|
Changeover time |
20 s, max.
|
Interference immunity |
According to EN 60947-1
|
Functions |
Star-delta contactor
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated insulation voltage (Ui) |
690 V
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V |
45 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
45 A
|
Rated operational current for specified heat dissipation (In) |
45 A
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
22 kW
|
Rated operational power (NEMA) |
0 kW
|
Static heat dissipation, non-current-dependent Pvs |
6.2 W
|
Suitable for |
Also motors with efficiency class IE3
|
Rated operational power at AC-3, 500 V, 50 Hz |
30 kW
|
Rated operational power at AC-3, 690 V, 50 Hz |
22 kW
|
Actuating voltage |
230 V 50 Hz, 240 V 60 Hz
|
Number of auxiliary contacts (change-over contacts) |
0
|
Voltage type of operating voltage |
AC
|
Operating voltage at AC, 50 Hz - min |
24 V
|
Operating voltage at AC, 50 Hz - max |
690 V
|
Operating voltage at AC, 60 Hz - min |
24 V
|
Operating voltage at AC, 60 Hz - max |
690 V
|
Operating voltage at DC - min |
0 V
|
Operating voltage at DC - max |
0 V
|