Eaton Moeller® series DILMF Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 25 A, 1 N/O, RAC 24: 24 V 50/60 Hz, Screw terminals
| Product Name | 
                                            
                                            
                                             
                                                Eaton Moeller® series DILMF contactor for semiconductor industries
                                             
                                         | 
                                    
| Catalog Number | 
                                            
                                            
                                             
                                                104442
                                             
                                         | 
                                    
| Model Code | 
                                            
                                            
                                             
                                                DILMF25-10(RAC24)
                                             
                                         | 
                                    
| EAN | 
                                            
                                            
                                             
                                                4015081042593
                                             
                                         | 
                                    
| Product Length/Depth | 
                                            
                                            
                                             
                                                97 mm
                                             
                                         | 
                                    
| Product Height | 
                                            
                                            
                                             
                                                85 mm
                                             
                                         | 
                                    
| Product Width | 
                                            
                                            
                                             
                                                45 mm
                                             
                                         | 
                                    
| Product Weight | 
                                            
                                            
                                             
                                                0.531 kg
                                             
                                         | 
                                    
| Certifications | 
                                            
                                            
                                             
                                                CSA  
                                        UL 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CSA File No.: 012528 UL UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 IEC/EN 60947-4-1 CE UL Category Control No.: NLDX  | 
                                    
| Catalog Notes | 
                                            
                                            
                                             
                                                Also tested according to AC-3e.
                                             
                                         | 
                                    
| Global Catalog | 
                                            
                                            
                                             
                                                104442
                                             
                                         | 
                                    
| Electrical connection type for auxiliary- and control-current circuit | 
                                            
                                            
                                             
                                                Screw connection
                                             
                                         | 
                                    
| Number of poles | 
                                            
                                            
                                             
                                                Three-pole
                                             
                                         | 
                                    
| 10.10 Temperature rise | 
                                            
                                            
                                             
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             
                                         | 
                                    
| 10.11 Short-circuit rating | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.12 Electromagnetic compatibility | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.13 Mechanical function | 
                                            
                                            
                                             
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             
                                         | 
                                    
| 10.2.2 Corrosion resistance | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.5 Lifting | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.6 Mechanical impact | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.7 Inscriptions | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.3 Degree of protection of assemblies | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.4 Clearances and creepage distances | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.5 Protection against electric shock | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.6 Incorporation of switching devices and components | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.7 Internal electrical circuits and connections | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.8 Connections for external conductors | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.2 Power-frequency electric strength | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.3 Impulse withstand voltage | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.4 Testing of enclosures made of insulating material | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| Fitted with: | 
                                            
                                            
                                             
                                                Built-in suppressor circuit
                                             
                                         | 
                                    
| Pollution degree | 
                                            
                                            
                                             
                                                3
                                             
                                         | 
                                    
| Utilization category | 
                                            
                                            
                                             
                                                AC-4: Normal AC induction motors: starting, plugging, reversing, inching  
                                        AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running  | 
                                    
| Connection | 
                                            
                                            
                                             
                                                Screw terminals
                                             
                                         | 
                                    
| Ambient operating temperature - max | 
                                            
                                            
                                             
                                                60 °C
                                             
                                         | 
                                    
| Ambient operating temperature - min | 
                                            
                                            
                                             
                                                -25 °C
                                             
                                         | 
                                    
| Ambient operating temperature (enclosed) - max | 
                                            
                                            
                                             
                                                40 °C
                                             
                                         | 
                                    
| Ambient operating temperature (enclosed) - min | 
                                            
                                            
                                             
                                                -25 °C
                                             
                                         | 
                                    
| Ambient storage temperature - max | 
                                            
                                            
                                             
                                                80 °C
                                             
                                         | 
                                    
| Ambient storage temperature - min | 
                                            
                                            
                                             
                                                -40 °C
                                             
                                         | 
                                    
| Assigned motor power at 115/120 V, 60 Hz, 1-phase | 
                                            
                                            
                                             
                                                2 HP
                                             
                                         | 
                                    
| Assigned motor power at 200/208 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                7.5 HP
                                             
                                         | 
                                    
| Assigned motor power at 230/240 V, 60 Hz, 1-phase | 
                                            
                                            
                                             
                                                5 HP
                                             
                                         | 
                                    
| Assigned motor power at 230/240 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                10 HP
                                             
                                         | 
                                    
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                15 HP
                                             
                                         | 
                                    
| Assigned motor power at 575/600 V, 60 Hz, 3-phase | 
                                            
                                            
                                             
                                                20 HP
                                             
                                         | 
                                    
| Conventional thermal current Ith (1-pole, enclosed) | 
                                            
                                            
                                             
                                                90 A
                                             
                                         | 
                                    
| Conventional thermal current Ith (3-pole, enclosed) | 
                                            
                                            
                                             
                                                36 A
                                             
                                         | 
                                    
| Conventional thermal current Ith of main contacts (1-pole, open) | 
                                            
                                            
                                             
                                                100 A
                                             
                                         | 
                                    
| Equipment heat dissipation, current-dependent Pvid | 
                                            
                                            
                                             
                                                4.2 W
                                             
                                         | 
                                    
| Heat dissipation capacity Pdiss | 
                                            
                                            
                                             
                                                0 W
                                             
                                         | 
                                    
| Heat dissipation per pole, current-dependent Pvid | 
                                            
                                            
                                             
                                                1.4 W
                                             
                                         | 
                                    
| Application | 
                                            
                                            
                                             
                                                Contactors for Semiconductor Industries acc. to SEMI F47
                                             
                                         | 
                                    
| Product category | 
                                            
                                            
                                             
                                                Contactors
                                             
                                         | 
                                    
| Electrical connection type of main circuit | 
                                            
                                            
                                             
                                                Screw connection
                                             
                                         | 
                                    
| Voltage type | 
                                            
                                            
                                             
                                                AC
                                             
                                         | 
                                    
| Number of auxiliary contacts (normally closed contacts) | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of auxiliary contacts (normally open contacts) | 
                                            
                                            
                                             
                                                1
                                             
                                         | 
                                    
| Number of contacts (normally closed) as main contact | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of contacts (normally open contacts) | 
                                            
                                            
                                             
                                                1
                                             
                                         | 
                                    
| Number of main contacts (normally open contact) | 
                                            
                                            
                                             
                                                3
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Drop-out voltage | 
                                            
                                            
                                             
                                                AC operated: 0.5 - 0.2 x UC, AC operated
                                             
                                         | 
                                    
| Overvoltage category | 
                                            
                                            
                                             
                                                III
                                             
                                         | 
                                    
| Duty factor | 
                                            
                                            
                                             
                                                100 %
                                             
                                         | 
                                    
| Emitted interference | 
                                            
                                            
                                             
                                                According to EN 60947-1
                                             
                                         | 
                                    
| Interference immunity | 
                                            
                                            
                                             
                                                According to EN 60947-1
                                             
                                         | 
                                    
| Pick-up voltage | 
                                            
                                            
                                             
                                                0.8 - 1.15 V AC x Uc
                                             
                                         | 
                                    
| Power consumption, pick-up, 50 Hz | 
                                            
                                            
                                             
                                                14 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
                                             
                                         | 
                                    
| Power consumption, sealing, 50 Hz | 
                                            
                                            
                                             
                                                0.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz  
                                        0.8 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz  | 
                                    
| Switching capacity (auxiliary contacts, general use) | 
                                            
                                            
                                             
                                                10 A, 600 V AC, (UL/CSA)  
                                        1 A, 250 V DC, (UL/CSA)  | 
                                    
| Switching capacity (auxiliary contacts, pilot duty) | 
                                            
                                            
                                             
                                                A600, AC operated (UL/CSA)  
                                        P300, DC operated (UL/CSA)  | 
                                    
| Switching capacity (main contacts, general use) | 
                                            
                                            
                                             
                                                40 A, Maximum motor rating (UL/CSA)
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated insulation voltage (Ui) | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 
                                            
                                            
                                             
                                                45 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 
                                            
                                            
                                             
                                                25 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 
                                            
                                            
                                             
                                                25 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 440 V | 
                                            
                                            
                                             
                                                25 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 500 V | 
                                            
                                            
                                             
                                                25 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 
                                            
                                            
                                             
                                                15 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 
                                            
                                            
                                             
                                                13 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-4, 400 V | 
                                            
                                            
                                             
                                                13 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-4, 440 V | 
                                            
                                            
                                             
                                                13 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-4, 500 V | 
                                            
                                            
                                             
                                                13 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-4, 660 V, 690 V | 
                                            
                                            
                                             
                                                10 A
                                             
                                         | 
                                    
| Rated operational current for specified heat dissipation (In) | 
                                            
                                            
                                             
                                                25 A
                                             
                                         | 
                                    
| Rated operational power at AC-3, 240 V, 50 Hz | 
                                            
                                            
                                             
                                                8.5 kW
                                             
                                         | 
                                    
| Rated operational power at AC-3, 380/400 V, 50 Hz | 
                                            
                                            
                                             
                                                11 kW
                                             
                                         | 
                                    
| Rated operational power at AC-3, 415 V, 50 Hz | 
                                            
                                            
                                             
                                                14.5 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 220/230 V, 50 Hz | 
                                            
                                            
                                             
                                                3.5 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 240 V, 50 Hz | 
                                            
                                            
                                             
                                                4 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 380/400 V, 50 Hz | 
                                            
                                            
                                             
                                                6 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 415 V, 50 Hz | 
                                            
                                            
                                             
                                                6.5 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 440 V, 50 Hz | 
                                            
                                            
                                             
                                                7 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 500 V, 50 Hz | 
                                            
                                            
                                             
                                                8 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 660/690 V, 50 Hz | 
                                            
                                            
                                             
                                                8.5 kW
                                             
                                         | 
                                    
| Rated operational power (NEMA) | 
                                            
                                            
                                             
                                                11 kW
                                             
                                         | 
                                    
| Resistance per pole | 
                                            
                                            
                                             
                                                2.65 mΩ
                                             
                                         | 
                                    
| Static heat dissipation, non-current-dependent Pvs | 
                                            
                                            
                                             
                                                0.8 W
                                             
                                         | 
                                    
| Switching time (AC operated, make contacts, closing delay) - max | 
                                            
                                            
                                             
                                                40 ms
                                             
                                         | 
                                    
| Switching time (AC operated, make contacts, opening delay) - max | 
                                            
                                            
                                             
                                                45 ms
                                             
                                         | 
                                    
| Short-circuit current rating (basic rating) | 
                                            
                                            
                                             
                                                125 A, max. CB, SCCR (UL/CSA)  
                                        5 kA, SCCR (UL/CSA) 125 A, max. Fuse, SCCR (UL/CSA)  | 
                                    
| Short-circuit current rating (high fault at 480 V) | 
                                            
                                            
                                             
                                                10/100 kA, Fuse, SCCR (UL/CSA)  
                                        10/65 kA, CB, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 125/70 A, Class J, max. Fuse, SCCR (UL/CSA)  | 
                                    
| Short-circuit current rating (high fault at 600 V) | 
                                            
                                            
                                             
                                                125/100 A, Class J, max. Fuse, SCCR (UL/CSA)  
                                        10/100 kA, Fuse, SCCR (UL/CSA) 10/22 kA, CB, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA)  | 
                                    
| Suitable for | 
                                            
                                            
                                             
                                                SEMI F47, Magnet systems  
                                        Also motors with efficiency class IE3  | 
                                    
| Special purpose rating of ballast electrical discharge lamps | 
                                            
                                            
                                             
                                                40 A (600V 60Hz 3phase, 347V 60Hz 1phase)  
                                        40 A (480V 60Hz 3phase, 277V 60Hz 1phase)  | 
                                    
| Special purpose rating of definite purpose rating | 
                                            
                                            
                                             
                                                25 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)  
                                        150 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)  | 
                                    
| Special purpose rating of elevator control | 
                                            
                                            
                                             
                                                15.2 A, 240 V 60 Hz 3-ph, (UL/CSA)  
                                        15 HP, 600 V 60 Hz 3-ph, (UL/CSA) 17 A, 600 V 60 Hz 3-ph, (UL/CSA) 5 HP, 240 V 60 Hz 3-ph, (UL/CSA) 3 HP, 200 V 60 Hz 3-ph, (UL/CSA) 10 HP, 480 V 60 Hz 3-ph, (UL/CSA) 11 A, 200 V 60 Hz 3-ph, (UL/CSA) 14 A, 480 V 60 Hz 3-ph, (UL/CSA)  | 
                                    
| Special purpose rating of refrigeration control (CSA only) | 
                                            
                                            
                                             
                                                240 A, LRA 480 V 60 Hz 3phase; (CSA)  
                                        180 A, LRA 600 V 60 Hz 3phase; (CSA) 40 A, FLA 480 V 60 Hz 3phase; (CSA) 30 A, FLA 600 V 60 Hz 3phase; (CSA)  | 
                                    
| Special purpose rating of resistance air heating | 
                                            
                                            
                                             
                                                40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)  
                                        40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)  | 
                                    
| Special purpose rating of tungsten incandescent lamps | 
                                            
                                            
                                             
                                                40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)  
                                        40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)  | 
                                    
| Conventional thermal current Ith at 40°C (3-pole, open) | 
                                            
                                            
                                             
                                                45 A
                                             
                                         | 
                                    
| Conventional thermal current Ith at 50°C (3-pole, open) | 
                                            
                                            
                                             
                                                43 A
                                             
                                         | 
                                    
| Conventional thermal current Ith at 60°C (3-pole, open) | 
                                            
                                            
                                             
                                                40 A
                                             
                                         | 
                                    
| Rated operational power at AC-3, 440 V, 50 Hz | 
                                            
                                            
                                             
                                                15.5 kW
                                             
                                         | 
                                    
| Rated operational power at AC-3, 500 V, 50 Hz | 
                                            
                                            
                                             
                                                17.5 kW
                                             
                                         | 
                                    
| Rated operational power at AC-3, 690 V, 50 Hz | 
                                            
                                            
                                             
                                                14 kW
                                             
                                         | 
                                    
| Actuating voltage | 
                                            
                                            
                                             
                                                RAC 24: 24 V 50/60 Hz
                                             
                                         | 
                                    
| Altitude | 
                                            
                                            
                                             
                                                Max. 2000 m
                                             
                                         | 
                                    
| Operating voltage at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                230 V
                                             
                                         | 
                                    
| Operating voltage at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Operating voltage at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                230 V
                                             
                                         | 
                                    
| Operating voltage at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         |