Eaton 93E UPS, Tower Online UPS, 100 kVA, 3 phase in/3 phase out, Power factor 0,9, Internal Maintenance Bypass Switch - 93E-100kVA-MBS
Product Name |
Eaton 93E UPS
|
Catalog Number |
93E100KMBS
|
Product Length/Depth |
600 mm
|
Product Height |
820 mm
|
Product Width |
1880 mm
|
Product Weight |
283 kg
|
Certifications |
CB
|
Audible alarms |
Yes
|
Auto shutdown function |
Yes
|
Internal battery included |
No
|
Battery charger type |
ABM technology
|
External battery connection |
Hardwired
|
BTU rating |
5745
|
Color |
Black
|
Communication |
Relay-MS, Network-MS, Modbus Card-MS
|
Construction type |
Free standing model
|
Efficiency (eco-mode) |
98 %
|
Improved efficiency mode |
High Efficiency
|
Number of communication slots |
2
|
Feed type |
AC
|
Form factor |
Tower
|
Hot-swappable power modules |
No
|
Input connection |
Fixed connection
|
Input current distortion |
5 %
|
Input nominal voltage |
400V default (380/400/415V)
|
Noise level (standard mode) |
<68 dBA at 1 meter
|
Number of output connections fixed connection |
1
|
Operating Temperature |
0°C - 40°C,Batteries recommended max. +25°C
|
Output frequency |
50 Hz (50/60 Hz programmable)
|
Output power factor |
.9
|
Output voltage regulation |
±1%
|
Overall efficiency |
94 %
|
Overload |
102–125% load 10 minutes, 126–150% load 1 minute, >151% load 500ms at 40oC
|
Package contents |
|
Parallelable |
Parallel for capacity and redundancy
|
Number of parallel units |
4
|
Phase (input) |
3
|
Phase (output) |
3
|
Potential free switch contact |
No
|
Rack mounting kit included |
No
|
Snmp |
No
|
Software compatibility |
IPP, IPM
|
Standard factory warranty |
1 year
|
Start-on-battery |
No
|
Storage temperature |
-15°C-55°C without batteries
|
Switch configuration |
Input, output, bypass, MBS, battery
|
Topology |
Online
|
Type Of Interface |
Other
|
Internal maintenance bypass |
Yes
|
User Interface (Hmi) |
5''LCD
|
kVA rating |
100 kVA
|
Voltage |
400Y/230V
|
Wattage |
90000 W
|
Number Of Output Connections With Protective Contact (Schuko) |
0
|
Application |
Data center/ facility/IT
|
Output effective power |
90 kW
|
Transition time for full load |
0 s
|
Efficiency (improved efficiency mode) |
0.98 %
|
Voltage distortion output (linear load) - max |
2 %
|
Integrated functionality |
Network Mangement
|
Input frequency - min |
50 Hz
|
Input frequency - max |
60 Hz
|
Input voltage - min |
380 V
|
Input voltage - max |
415 V
|
Output voltage - min |
380 V
|
Output voltage - max |
415 V
|
Secondary Frequency Min |
50 Hz
|
Secondary Frequency Max |
60 Hz
|
Output apparent power |
100000 VA
|
Primary frequency - max |
60 Hz
|
Primary frequency - min |
50 Hz
|
Runtime at half load |
0 min
|
Runtime at full load |
0 min
|
Mounting Method |
Tower
|
Degree of Protection |
IP20
|