Descargar documento () de 20
Descontinuado

256284

Eaton Moeller® series EASY Connecting cable for networking devices via easyNet, 2xRJ45, 80cm

General specifications

Product Name
Eaton Moeller® series EASY Accessory Connection cable
Catalog Number
256284
EAN
4015082562847
Product Length/Depth
800 mm
Product Height
5 mm
Product Width
5 mm
Product Weight
0.027 kg
Certifications
CE
CSA
UL
UL Category Control No.: NRAQ
CSA File No.: 012528
CSA-C22.2 No. 142-M1987
UL File No.: E135462
CSA Class No.: 2258-02
CSA-C22.2 No. 213-M1987
UL 508

Especificaciones del producto

Type
0.3m networking cable
Suitable as
Signaling cable
Features
Halogen free (acc. EN 60754-1/2)
UV resistant
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Cable type
Pairs 2 x 0.14 mm², max. 0.49 mm (Cu wire bare 7 x 0.16 mm²)
Conductor category
Class 2 = stranded
Cable category
5E
Reaction-to-fire class (EN 13501-6)
None
Specification material outer sheath
Other
Stranding
Bundle
Stranding element
Pairs
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Nominal cross section (conductor)
0.14 mm²
Number of cores
8
Number of stranding elements
2
NVP value
67 %
Outer diameter - approximate
4.5 mm
Permitted bending radius, moving application with forced guidance - min
120 mm
Permitted bending radius, moving application with free movement - min
120 mm
Permitted bending radius, stationary application/permanent installation - min
120 mm
Permitted temperature of outer cable (assembled) without vibration - max
60 °C
Permitted temperature of outer cable (assembled) without vibration - min
-25 °C
Permitted temperature of outer cable (assembling/handling) - max
60 °C
Permitted temperature of outer cable (assembling/handling) - min
-25 °C
Circuit integrity
None
Approved type of underground installation
Other
Material reinforcement
Other
Armouring/reinforcement
None
Cable geometry
Round
Conductor material
Other
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
Conductor diameter
4.5 mm
AWG-size
26
Cable length
800 m
Connection
Connection cable for XC200 to interface switch
Conductor surface
Bare
Core identification
Colour
Core insulation material
Other
Euro class acidity (EN 13501-6)
None
Euro class flaming droplets/particles (EN 13501-6)
None
Material
E-Cu 58 F21 (according to DIN 40500 Part 4)
Flame retardant
No
Outer sheath color
Gray
Outer sheath material
Other
Protective sheath material
Other
Screen over stranding
None
Screen over stranding element
Foil
Smoke development class (EN 13501-6)
None

Exportar especificación del producto

eCAD model

Guías de especificaciones de producto

Videos de instalación

Nota: Si faltan archivos en la descarga .zip, el tipo de archivo no es compatible con la descarga masiva.