Eaton xComfort KLV LV systems Final Distribution Boards. Hollow wall compact distribution board, 3-rows, super-slim sheet steel door, 36HW-SF
| Product Name |
Eaton xComfort KLV energy distribution board
|
| Catalog Number |
184803
|
| EAN |
4015081788392
|
| Product Length/Depth |
100 mm
|
| Product Height |
590 mm
|
| Product Width |
360 mm
|
| Product Weight |
3.99 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC/EN 60670-24 (PD)
IEC/EN 62208 |
| Model Code |
KLV-36HW-SF
|
| Features |
EMC-version
|
| Fitted with: |
Door/Frame
Imprintable sheet Nail lugs Wall trough Front cover Spirit level for leveling Installation instructions 3D adjustment element for mounting designed to adjust the mounting depth by up to 18 mm Device support rails |
| Functions |
Extension possible
Basic device Sealable |
| Protection class |
II (totally insulated)
|
| RAL-number |
9016
|
| Special features |
IP30
Protection Class II
Plastic enclosure with sheet steel door, white (RAL 9016)
|
| Used with |
Installation distribution board
KLV energy Basic device |
| Application |
Indoor (installation site)
|
| Color |
White
Traffic white (RAL 9016) |
| Type |
Basic device
Installation distribution board
KLV energy
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
Meets the product standard's requirements.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
850 °C; meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Not relevant to indoor installations.
|
| 10.2.5 Lifting |
Does not apply to enclosures without lifting aids.
|
| 10.2.6 Mechanical impact |
IK05
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
IP30
|
| 10.4 Clearances and creepage distances |
Is the panel builder's responsibility.
|
| 10.5 Protection against electric shock |
Protection class 2, therefore not applicable.
|
| 10.6 Incorporation of switching devices and components |
Is the panel builder's responsibility.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Ui = 400 V AC
|
| 10.9.3 Impulse withstand voltage |
4 kV
|
| 10.9.4 Testing of enclosures made of insulating material |
Meets the product standard's requirements.
|
| Ambient operating temperature details |
-5 °C - 40 °C
|
| Frequency rating of contacts |
50 Hz
|
| Built-in depth |
88 mm
|
| Cable entry postion |
Cable entries on top and bottom, side, back plate
|
| Closure type |
Other
|
| Cover/door color |
White
|
| Cover/door model |
With notch
|
| Cover/door type |
Door
Single |
| Degree of protection |
IP30
IK05 (impact resistance) |
| Enclosure material |
Plastic
|
| Internal depth |
75 mm
|
| Material |
Sheet steel, powder-coated
Polystyren (plastic) |
| Module rack type |
Rail frame
|
| Number of module space units per row |
12
|
| Number of rows |
3
|
| Protective shrouding material |
Plastic
|
| Width in number of modular spacings |
12
|
| Mounting method |
DIN-rail
Flush mounting Hollow wall Hollow-wall mounting |
| Heat diss. ambient 35°C delta T:20°C flush mount individ. encl. top(IEC 60890) |
38 W
|
| Heat diss. ambient 35°C delta T:35°C flush mount individ. encl. top(IEC 60890) |
48 W
|