Otsing teabebaasis
Lae dokument alla () … 20
We make what matters work*

199452
Mudeli kood: EASY-COM-SWD-C1

Eaton EASY Communication module for connecting the easy control relay as SWD coordinator in SmartWire-DT applications, screw terminal

General specifications

Product Name
Eaton Moeller® series EASY Accessory Bus module
Catalog Number
199452
EAN
4015081978434
Product Length/Depth
58 mm
Product Height
90 mm
Product Width
36 mm
Product Weight
0.1 kg
Certifications
IEC 60068-2-27
IEC 60068-2-6
IEC/EN 61131-2
IEC/EN 61000-4-2
IEC/EN 61000-6-2
IEC/EN 61000-6-3
EN 61010
EN 50178
CE
UL Listed
UL File No.: E205091
UL hazardous location group C (ethylene)
UL hazardous location group A (acetylene)
UL hazardous location group B (hydrogen)
UL hazardous location class I
UL hazardous location group D (propane)
UL hazardous location division 2
Catalog Notes
Current consumption at 24 V DC
Model Code
EASY-COM-SWD-C1

Features & Functions

Features
Expansion device
Expandable

General information

Degree of protection
IP20
Insulation resistance
According to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Mounting method
Front build in possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting
Rail mounting possible
Mounting method
Front build in possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting
Rail mounting possible
Overvoltage category
II
Pollution degree
2
Product category
Control relays easyE4
Protocol
TCP/IP
Other bus systems
Residual ripple
≤ 5 %
≤ 5 % (input voltage)
Type
Communication module
Voltage type
DC

Ambient conditions, mechanical

Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
Horizontal
Vertical
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Environmental conditions
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Condensation: prevent with appropriate measures
Relative humidity
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)

Electro magnetic compatibility

Air discharge
8 kV
Burst impulse
1 kV, SmartWire-DT cable, Signal cable, according to IEC/EN 61131-2, Level 3
Contact discharge
6 kV, Electrostatic discharge (ESD)
Electromagnetic fields
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)
Radio interference class
Class B (EN 61000-6-3)
Surge rating
1 kV, Supply cables, asymmetrical, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
0.5 kV, Supply cables, symmetrical, power pulses (Surge), EMC
Voltage dips
According to EN 61131-2
≤ 10 ms

Terminal capacities

Terminal capacity
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule
Screwdriver size
3.5 x 0.8 mm, Terminal screw
Tightening torque
0.6 Nm, Screw terminals

Electrical rating

Heat dissipation
1 W (at 24 V DC)
Inrush current
12.5 A (for 6 ms)
Power consumption
14.5 W
Rated control supply voltage
24 V DC (UAUX, -15 %/+20 %)
20.4 - 28.8 V DC
Rated operational voltage
24 V DC (-15 %/+ 20 % - power supply)
Supply current
0.7 A, Imax, SmartWire-DT supply
2 A (UL), Imax, Supply voltage UAux
Supply voltage at DC - min
20.4 VDC
Supply voltage at DC - max
28.8 VDC
Voltage rating
24 Vdc

Short-circuit rating

Short-circuit protection
No, Short-circuit rating, Supply voltage UAux
Yes, SmartWire-DT supply voltage
≥ 3 A (T) (e.g. FAZ C3), Fuse, Power supply

Communication

Addressing
Address set automatically via Configuration button
Bus termination
Integrated in the device, SmartWire-DT
With SWD4-RC8-10, SmartWire-DT line end
Connection
SmartWire-DT blade terminal SWD4-8MF2
Connection type
SWD: Plug, 8-pole
Screw terminal
Data transfer rate
125 kBit/s, SmartWire-DT
250 kBit/s, SmartWire-DT
LED indicator
Status indication of SmartWire-DT master: Green and red LEDs
Station
SmartWire-DT master, SmartWire-DT network

Input/Output

Input current
500 mA (Uₑ)
Number of inputs (analog)
0
Number of inputs (digital)
0
Number of outputs (analog)
0
Number of outputs (digital)
0
Output voltage
Uₑ - 0.3 V (SWD-OUT, Supply voltage UAUX)

Safety

Explosion safety category for gas
None
Potential isolation
Between SmartWire-DT supply voltage and Power supply POW: no
Between SmartWire-DT supply voltage and AUX: yes
Between Supply voltage UAUX and SmartWire-DT: yes
Between supply voltage UAUX and Power supply POW: yes
Between SmartWire-DT supply voltage and COM Interface: yes
Protection against polarity reversal
Yes
Explosion safety category for dust
None

Design verification

Equipment heat dissipation, current-dependent Pvid
10.5 W
Static heat dissipation, non-current-dependent Pvs
4 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Ekspordi toote tehnilised andmed

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Autentige toode

Sisestage oma 16–17-kohaline seerianumber
Sisestatud seerianumber ei tohiks sisaldada erimärke. Sisestatud seerianumber on vale, see peaks olema 16- või 17-kohaline. Sisestatud seerianumbrit ei leitud. Proovige uuesti või teatage sellest probleemist edasise abi saamiseks. Sisestatud seerianumber ei vasta tootele. Kontrollige oma toote seerianumbrit ja proovige uuesti. Klõpsake siin sisestatud seerianumbriga tootelehele navigeerimiseks Eatonile on teada, et seerianumber on kahtlane, palun proovige uuesti või teatage sellest probleemist edasise abi saamiseks.
Seerianumber
Lähtestamine Eatonile on teada, et seerianumber on kahtlane, palun proovige uuesti või teatage sellest probleemist edasise abi saamiseks. Eaton ei tunne seerianumbrit ära ja see on kehtetu. Palun kasutage seda vormi, et teatage sellest probleemist edasise abi saamiseks.
Sisestage 6-kohaline autentimiskood
Sisestatud toode on kahtlane! Proovige uuesti või teatage sellest probleemist edasise abi saamiseks. Sisestatud autentimiskood ei vasta meie andmetele selle seerianumbri kohta. Proovige uuesti või teatage sellest probleemist edasise abi saamiseks. Kehtetu autentimiskood. Pikkus peab olema 6 tähemärki teatage sellest probleemist edasise abi saamiseks. Autentimiskood on nõutav teatage sellest probleemist edasise abi saamiseks.
Enne autentimist sooritage Captcha test.
Võtke meiega ühendust probleemist teatama
x
Teatage probleemist
Palun sisesta oma täisnimi.
x
Täname teid, teie taotlus on esitatud, meie tootemeeskond võtab teiega peagi ühendust.
Märkus: Kui ZIP-vormingus allalaadimisel puuduvad failid, siis hulgiallalaadimine seda failitüüpi ei toeta.