Oil fuse-link, medium voltage, 6.3 A, AC 12 kV, BS2692 F02, 359 x 63.5 mm, back-up, BS, IEC, ESI, with striker
| Product Name | 
                                                Eaton Bussmann series medium voltage oil fuse
                                             | 
| Catalog Number | 
                                                12OHGMA6.3
                                             | 
| UPC | 
                                                051712585491
                                             | 
| EAN | 
                                                5027590432801
                                             | 
| Product Length/Depth | 
                                                359 mm
                                             | 
| Product Height | 
                                                63.5 mm
                                             | 
| Product Width | 
                                                63.5 mm
                                             | 
| Product Weight | 
                                                2600 g
                                             | 
| Compliances | 
                                                BS 2692-1  ESI 12-8 | 
| Certifications | 
                                                IEC Rated  IEC60282-1 KEMA | 
| Amperage Rating | 
                                                6.3 A
                                             | 
| Fuse indicator | 
                                                with striker
                                             | 
| Fuse size | 
                                                63.5 x 359 mm
                                             | 
| Breaking capacity | 
                                                40 kA
                                             | 
| Installation technique | 
                                                Oil
                                             | 
| Performance Cat According To IEC 60282-1 | 
                                                Back-up
                                             | 
| Product application | 
                                                Primary side transformer protection
                                             | 
| Rated frequency - max | 
                                                60 Hz
                                             | 
| Rated frequency - min | 
                                                50 Hz
                                             | 
| Release characteristic | 
                                                Other
                                             | 
| Standard | 
                                                British Standard
                                             | 
| Utilization category | 
                                                Other
                                             | 
| Voltage type | 
                                                AC
                                             | 
| With striker | 
                                                Yes
                                             | 
| Fuse diameter | 
                                                63.5 mm
                                             | 
| Joule integral (I2T) - max operating | 
                                                6.1 x 102
                                             | 
| Joule integral (I2T) - min pre-arcing | 
                                                2 x 101
                                             | 
| Resistance | 
                                                520
                                             | 
| Class | 
                                                Class back-up
                                             | 
| Barrels | 
                                                1
                                             | 
| Construction type | 
                                                F02/BS 2692
                                             | 
| Fuse shape | 
                                                Cylindrical
                                             | 
| Interrupt rating | 
                                                40 kAIC
                                             | 
| Construction size | 
                                                63.5 x 359 mm
                                             | 
| Voltage rating | 
                                                12 kV
                                             | 
| Type | 
                                                fuse
                                             | 
| Application | 
                                                protection of primary side transformer, and oil-filled fuse switch combination unit
                                             | 
| Fuse type | 
                                                OHGM
                                             |