문서 다운로드 () / 20

167677
모델 코드: LS-S02-CC/RL

Eaton Moeller® series LS Position switches, 2N/C, rotary lever, snap-action contact, Cold Climate -40°C

일반 규범

Product Name
Eaton Moeller® series LS Rotary lever
Catalog Number
167677
Model Code
LS-S02-CC/RL
EAN
4015081642199
Product Length/Depth
110 mm
Product Height
46 mm
Product Width
31 mm
Product Weight
0.066 kg
Certifications
IEC/EN 60947-5
UL
UL File No.: E29184
CSA
UL Category Control No.: NKCR
CSA Class No.: 3211-03
CSA-C22.2 No. 14
CE
CSA File No.: 012528
IEC/EN 60947
UL 508
Catalog Notes
  • Contacts with safety function, by positive opening to IEC/EN 60947-5-1
  • Contains a silicone seal to increase resistance to ozone, detergents and disinfectants.

특징 및 기능

Design
EN 50047 Form A
Enclosure color
Yellow Cover
Enclosure material
Insulated material
Features
The operating head can be rotated 90° to enable adaptation to the specified approach direction
Positive opening

일반

Connection type
Screwed terminal
Degree of protection
NEMA 13
IP67
NEMA 4X (indoor use only)
NEMA 12
IP66
NEMA 3R
Lifespan, mechanical
8,000,000 Operations
Operating frequency
6000 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Rotary lever
Rated impulse withstand voltage (Uimp)
4000 V AC
Repetition accuracy
0.15 mm (Contacts/switching capacity)
Type
  • Position switch
  • Safety position switch

주변 조건, 기계적 조건

Mounting position
As required
Shock resistance
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms

기후 환경 조건

Ambient operating temperature - min
-40 °C
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

단자 용량

Terminal capacity (flexible with ferrule)
1 x (0.5 - 1.5) mm²
Terminal capacity (solid)
1 x (0.5 - 2.5) mm²

전기 정격

Rated insulation voltage (Ui)
400 V
Rated operational current (Ie)
6 A at AC-15, 220 V 230 V 240 V
3 A at 24 V
0.3 A at 220 V
0.6 A at 110 V
4 A at AC-15, 380 V 400 V 415 V
6 A at AC-15, 24 V
Short-circuit protection rating
Max. 6 A gG/gL, Fuse, Contacts
Supply frequency
Max. 400 Hz, Contacts

액추에이터

Actuating force at beginning/end of stroke
1.0 N/8.0 N
Actuating torque of rotary drives
0.2 Nm
Actuator type
Rotary lever
Operating speed
Max. 1.5 m/s (with DIN cam, mechanical actuation)

접점

Control circuit reliability
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
Number of contacts (normally closed contacts)
2

설계 검증

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.17 W
Rated operational current for specified heat dissipation (In)
6 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

제품 사양 내보내기