Eaton Moeller® series MSC-DE DOL starter, 380 V 400 V 415 V: 4 kW, Iq= 100 kA, Ir= 3 - 12 A, 24 V DC, DC voltage
Product Name |
Eaton Moeller® series MSC-DE DOL starter
|
Catalog Number |
121742
|
EAN |
4015081195527
|
Product Length/Depth |
102 mm
|
Product Height |
198 mm
|
Product Width |
45 mm
|
Product Weight |
0.78 kg
|
Certifications |
VDE 0660
IEC/EN 60947-4-1 |
Model Code |
MSC-DE-12-M9(24VDC)
|
Fitted with: |
Short-circuit release
|
Functions |
Temperature compensated overload protection
|
Class |
Adjustable
|
Connection |
Screw terminals
|
Connection to SmartWire-DT |
No
|
Coordination type |
1
|
Current flow times - min |
500 (Class 5) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths Note: Going below the minimum current flow time can cause overheating of the load (motor). For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. 700 (Class 10) AC-4 cycle operation, Main conducting paths 1000 (Class 20) AC-4 cycle operation, Main conducting paths |
Cut-out periods - min |
≤ 500 ms, main conducting paths, AC-4 cycle operation
|
Degree of protection |
IP20
NEMA Other |
Model |
IEC starter
|
Mounting method |
DIN rail
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
1
|
Overload release current setting - min |
3 A
|
Overload release current setting - max |
12 A
|
Overvoltage category |
III
|
Pollution degree |
3
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Suitable for |
Also motors with efficiency class IE3
|
Type |
Starter with electronic trip unit
|
Voltage type |
DC
|
Altitude |
Max. 2000 m
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Rated operational current (Ie) |
8.5 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
9 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
2.2 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
4 kW
|
Rated operational voltage |
230 - 415 V AC
|
Short-circuit current rating (basic rating) |
5 kA, SCCR (UL/CSA)
200 A, max. CB, SCCR (UL/CSA) 225 A, max. Fuse, SCCR (UL/CSA) |
Short-circuit release (Irm) - max |
186 A
|
Power consumption (sealing) at DC |
2.6 W
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Equipment heat dissipation, current-dependent Pvid |
2.4 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.8 W
|
Rated operational current for specified heat dissipation (In) |
9 A
|
Static heat dissipation, non-current-dependent Pvs |
2.6 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|