Eaton XN Base module washer XI/ON, for feeder unit, tension spring, 4 connection levels
| Product Name | 
                                                Eaton XN Rack
                                             | 
| Catalog Number | 
                                                140076
                                             | 
| Model Code | 
                                                XN-P4T-SBBC
                                             | 
| EAN | 
                                                7640130120990
                                             | 
| Product Length/Depth | 
                                                128.9 mm
                                             | 
| Product Height | 
                                                49.9 mm
                                             | 
| Product Width | 
                                                12.6 mm
                                             | 
| Product Weight | 
                                                0.035 kg
                                             | 
| Compliances | 
                                                RoHS Compliant  CE Marked | 
| Certifications | 
                                                UL Listed  IEC/EN 61000-6-2 Rated data for terminations according to IEC/EN 60947-7-1 UL Category Control No.: NRAQ, NRAQ7 IEC/EN 6113-2 CE UL File No.: E205091 CSA-C22.2 No. 142 CE, cUL UL Recognized UL 508 Certified by UL for use in Canada IEC/EN 61131-2 CSA Class No.: 2252-01, 2252-81 UL report applies to both US and Canada IEC/EN 61000-6-4 | 
| Catalog Notes | 
                                                Base module for the gateway supply (with XN‑BR-24V DC-D)
                                             | 
| Color | 
                                                Gray
                                             | 
| Fitted with: | 
                                                Pluggable modules, central modules  Pluggable modules, others Power supply | 
| Degree of protection | 
                                                IP20
                                             | 
| Mounting method | 
                                                Rail mounting possible
                                             | 
| Number of connection levels | 
                                                4
                                             | 
| Type | 
                                                XI/ON slice card base module
                                             | 
| Used with | 
                                                XN-PF-120/230VAC-D  XN-BR-24VDC-D XN-PF-24VDC-D | 
| Voltage type | 
                                                DC
                                             | 
| Drop and topple | 
                                                According to IEC 60068-2-31, free fall according to IEC 60068-2-32
                                             | 
| Shock resistance | 
                                                Continuous according to IEC/EN 60068-2-29  Mechanical, According to IEC/EN 60068-2-27 | 
| Vibration resistance | 
                                                According to IEC/EN 60068-2-6
                                             | 
| Ambient operating temperature - min | 
                                                0 °C
                                             | 
| Ambient operating temperature - max | 
                                                55 °C
                                             | 
| Environmental conditions | 
                                                Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)  Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation) | 
| Relative humidity | 
                                                5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
                                             | 
| Air discharge | 
                                                Air/contact discharge according to IEC/EN 61000-4-2
                                             | 
| Burst impulse | 
                                                According to IEC/EN 61000-4-4
                                             | 
| Electromagnetic fields | 
                                                According to IEC EN 61100-4-2
                                             | 
| Emitted interference | 
                                                30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)  230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3) | 
| Radiated RFI | 
                                                IEC/EN 61100-4-6
                                             | 
| Surge rating | 
                                                According to IEC/EN 61000-4-5 Level 4
                                             | 
| Voltage dips | 
                                                According to EN 61131-2 (Voltage fluctuations/voltage dips)
                                             | 
| Terminal capacity | 
                                                0.5 - 2.5 mm², solid, H07V-U  0.5 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) 0.5 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) 0.5 - 1.5 mm², flexible without ferrule, H07V-K | 
| Terminals | 
                                                Spring cage
                                             | 
| Gauge pin | 
                                                A1 (according to IEC/EN 60947-1)
                                             | 
| Stripping length (main cable) | 
                                                8 mm
                                             | 
| Connection | 
                                                Four-level
                                             | 
| Connection type | 
                                                Spring-loaded/screw terminal, Connection design in TOP direction
                                             | 
| Number of slots | 
                                                1
                                             | 
| Input current at AC - max | 
                                                0 A
                                             | 
| Input voltage at AC 50 Hz - min | 
                                                0 V
                                             | 
| Input voltage at AC 50 Hz - max | 
                                                0 V
                                             | 
| Input voltage at DC - min | 
                                                0 V
                                             | 
| Input voltage at DC - max | 
                                                0 V
                                             | 
| Output current at AC, 50 Hz - max | 
                                                0 A
                                             | 
| Output voltage at AC 50 Hz - max | 
                                                0 V
                                             | 
| Output voltage at DC - min | 
                                                0 V
                                             | 
| Output voltage at DC - max | 
                                                0 V
                                             | 
| Explosion safety category for dust | 
                                                None
                                             | 
| Explosion safety category for gas | 
                                                None
                                             | 
| Potential isolation | 
                                                Through optocoupler: yes
                                             | 
| Equipment heat dissipation, current-dependent Pvid | 
                                                0 W
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Heat dissipation per pole, current-dependent Pvid | 
                                                0 W
                                             | 
| Rated operational current for specified heat dissipation (In) | 
                                                0 A
                                             | 
| Static heat dissipation, non-current-dependent Pvs | 
                                                0 W
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Meets the product standard's requirements.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             |