Eaton Moeller® series E59 Proximity switch, inductive, 1N/O, Sn=18mm, 4L, 6-48VDC, NPN, PNP, M18, metal E59-M18C116C02-D1
| Product Name | 
                                            
                                            
                                             
                                                Eaton E59 AccuProx analog inductive proximity sensor
                                             
                                         | 
                                    
| Catalog Number | 
                                            
                                            
                                             
                                                136217
                                             
                                         | 
                                    
| EAN | 
                                            
                                            
                                             
                                                4015081330102
                                             
                                         | 
                                    
| Product Length/Depth | 
                                            
                                            
                                             
                                                152.4 mm
                                             
                                         | 
                                    
| Product Height | 
                                            
                                            
                                             
                                                44.45 mm
                                             
                                         | 
                                    
| Product Width | 
                                            
                                            
                                             
                                                127 mm
                                             
                                         | 
                                    
| Product Weight | 
                                            
                                            
                                             
                                                0.45 kg
                                             
                                         | 
                                    
| Certifications | 
                                            
                                            
                                             
                                                CSA File No.: UL report applies to both US and Canada  
                                        UL 508 CE Certified by UL for use in Canada UL Category Control No.: NRKH, NRKH7 UL File No.: E166051 CSA-C22.2 No. 14 IEC/EN 60947-5-2 UL  | 
                                    
| Model Code | 
                                            
                                            
                                             
                                                E59-M18C116C02-D1
                                             
                                         | 
                                    
| Type | 
                                            
                                            
                                             
                                                Inductive sensor
                                             
                                         | 
                                    
| Electric connection type | 
                                            
                                            
                                             
                                                Cable
                                             
                                         | 
                                    
| Enclosure material finishing | 
                                            
                                            
                                             
                                                Other
                                             
                                         | 
                                    
| Actuation type | 
                                            
                                            
                                             
                                                Metallic Target
                                             
                                         | 
                                    
| Enclosure material | 
                                            
                                            
                                             
                                                Metal
                                             
                                         | 
                                    
| Enclosure type | 
                                            
                                            
                                             
                                                Cylinder, screw-thread
                                             
                                         | 
                                    
| Category (EN 954-1) | 
                                            
                                            
                                             
                                                B
                                             
                                         | 
                                    
| Explosion safety category for dust | 
                                            
                                            
                                             
                                                None
                                             
                                         | 
                                    
| Explosion safety category for gas | 
                                            
                                            
                                             
                                                None
                                             
                                         | 
                                    
| Safety performance level (EN ISO 13849-1) | 
                                            
                                            
                                             
                                                None
                                             
                                         | 
                                    
| SIL (IEC 61508) | 
                                            
                                            
                                             
                                                None
                                             
                                         | 
                                    
| Ambient operating temperature - max | 
                                            
                                            
                                             
                                                70 °C
                                             
                                         | 
                                    
| Ambient operating temperature - min | 
                                            
                                            
                                             
                                                -40 °C
                                             
                                         | 
                                    
| Diameter sensor | 
                                            
                                            
                                             
                                                18 mm
                                             
                                         | 
                                    
| Number of contact energized outputs with signalling function | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of contacts (normally open contacts) | 
                                            
                                            
                                             
                                                1
                                             
                                         | 
                                    
| Number of outputs (protected contact energized) | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of outputs (protected semiconductor) | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of outputs (semiconductor with signaling function) | 
                                            
                                            
                                             
                                                1
                                             
                                         | 
                                    
| Operational current (Ib) in the switched state at 24 V DC | 
                                            
                                            
                                             
                                                15 A
                                             
                                         | 
                                    
| Functions | 
                                            
                                            
                                             
                                                Protection against polarity reversal  
                                        Short-circuit protection Protection against wire breakage  | 
                                    
| Voltage type | 
                                            
                                            
                                             
                                                DC
                                             
                                         | 
                                    
| Mounting method | 
                                            
                                            
                                             
                                                Non-flush mounting
                                             
                                         | 
                                    
| Material | 
                                            
                                            
                                             
                                                Stainless steel
                                             
                                         | 
                                    
| Connection type | 
                                            
                                            
                                             
                                                2 m connection cable  
                                        3-wire  | 
                                    
| Installation type | 
                                            
                                            
                                             
                                                Not flat
                                             
                                         | 
                                    
| Degree of protection | 
                                            
                                            
                                             
                                                IP67  
                                        IP69 NEMA 4X, 6, 13  | 
                                    
| Interface type | 
                                            
                                            
                                             
                                                None
                                             
                                         | 
                                    
| LED indicator | 
                                            
                                            
                                             
                                                Status indication of Switching state: Red LED  
                                        Status indication of Operating voltage: Green LED  | 
                                    
| Switch function type | 
                                            
                                            
                                             
                                                Normally open contact
                                             
                                         | 
                                    
| Load current | 
                                            
                                            
                                             
                                                1 - 300 mA (Ie)
                                             
                                         | 
                                    
| Residual current | 
                                            
                                            
                                             
                                                0.15 mA (through the load in the blocked state at 230 V AC and 24 V DC)
                                             
                                         | 
                                    
| Shock resistance | 
                                            
                                            
                                             
                                                30 g, Mechanical, Shock duration 11 ms
                                             
                                         | 
                                    
| Switching frequency | 
                                            
                                            
                                             
                                                150 Hz
                                             
                                         | 
                                    
| Voltage rating - max | 
                                            
                                            
                                             
                                                48 V
                                             
                                         | 
                                    
| Product category | 
                                            
                                            
                                             
                                                iProx Series
                                             
                                         | 
                                    
| Switching output type | 
                                            
                                            
                                             
                                                PNP
                                             
                                         | 
                                    
| Temperature drift of sn | 
                                            
                                            
                                             
                                                10 %
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - max | 
                                            
                                            
                                             
                                                48 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - min | 
                                            
                                            
                                             
                                                6 V
                                             
                                         | 
                                    
| Rated switching distance (Sn) - max | 
                                            
                                            
                                             
                                                18 mm
                                             
                                         | 
                                    
| Repeatability | 
                                            
                                            
                                             
                                                3 %
                                             
                                         | 
                                    
| Sensor length | 
                                            
                                            
                                             
                                                64 mm
                                             
                                         | 
                                    
| Supply voltage - max | 
                                            
                                            
                                             
                                                48 V
                                             
                                         | 
                                    
| Supply voltage - min | 
                                            
                                            
                                             
                                                6 V
                                             
                                         | 
                                    
| Switching hysteresis of Sn | 
                                            
                                            
                                             
                                                15 %
                                             
                                         | 
                                    
| Voltage drop (Ud) | 
                                            
                                            
                                             
                                                2.5 V
                                             
                                         |